Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: BAMA CHEX, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BAMA CHEX, INC. in 724 2ND AVE NW, CULLMAN, AL 35055 (NAICS 722211). OSHA activity number 339899031.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bama Chex, INC. for free Get an email when a new federal OSHA severe-injury report for Bama Chex, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
BAMA CHEX, INC.
Site address
724 2ND AVE NW
City
CULLMAN
State
AL
ZIP
35055
Mailing
566 COUNTY ROAD 3986, JASPER, AL 35503
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722211
Employees
11
Ownership type
Private (A)

4 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 4 exposed
Issued
Sep 25, 2014
Abate by
Oct 7, 2014
Penalty
Initial $1,200 · Current $1,200
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition:  (a) On or about 08/13/14 - t 724 2nd Ave NW, Cullman, AL, the roof had been leaking on the right side of the building.
Recent events (1)
  • · Z (S) $1200

1910.157 C01

Serious Gravity 1 1 instance 4 exposed
Issued
Sep 25, 2014
Abate by
Oct 3, 2014
Penalty
Initial $1,200 · Current $1,200
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  (a) On or about 08/13/14 - 724 2nd Ave NW, Cullman, AL, two portable fire extinguishers were stored on the floor.
Recent events (1)
  • · Z (S) $1200

1910.157 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 25, 2014
Abate by
Oct 1, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(1): The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace:  (a) On or about 08/13/14 - 724 2nd Ave NW, Cullman, AL, the 10 pound portable fire extinguisher's seal was broken and the pressure was low.
Recent events (1)
  • · Z (S) $0

1910.303 C03 I

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 25, 2014
Abate by
Oct 3, 2014
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.303(c)(3)(i): Conductors shall be spliced or joined with splicing devices identified for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soldered splices shall first be spliced or joined to be mechanically and electrically secure without solder and then soldered. All splices and joints and the free ends of conductors shall be covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose:    (a) On or about 08/13/14 - 724 2nd Ave NW, Cullman, AL, the electrical cord located inside of the freezer was spliced together and covered with electrical tape.
Recent events (1)
  • · Z (S) $1600

View Bama Chex, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339899031.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.