ALBANY, NY —
OSHA Inspection: LATHAM SEAMLESS GUTTERS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LATHAM SEAMLESS GUTTERS, INC. in 23 MULBERRY ST., ALBANY, NY 12205 (NAICS 238170). OSHA activity number 339899239.
Where did this inspection happen?
- Establishment
- LATHAM SEAMLESS GUTTERS, INC.
- Site address
- 23 MULBERRY ST.
- City
- ALBANY
- State
- NY
- ZIP
- 12205
- Mailing
- 20 RESERVOIR RD., ALTAMONT, NY 12009
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 10
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1960.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about July 29, 2014 and at times prior thereto at the work site; an employee was installing gutters on a 10 on 12 pitched roof approximately 16' from the ground to its lower eave, without the use of fall protection.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On or about July 29, 2014 and at times prior thereto at the work site; an employee was accessing the approximately 21' roof with an extension ladder with its side rails extending approximately 2' above the landing surface.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1926.1053 B13
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) On or about July 29, 2014 and at times prior thereto at the work site; an employee was using the top and top step of an 8' A-frame ladder as a step during installation of a gutter.
Recent events (2)
- — I (S) $0
- — Z (S) $1600
More inspections in this industry (NAICS 238170)
CLINTON, MO—2026-07-14 00:00:00
TORCHYLO BUILDERS, LLC.
HIGH POINT, NC—2026-07-14 00:00:00
161545 - RHP SIDING LLC
HIGH POINT, NC—2026-07-14 00:00:00
161544 - TRIAD SIDING OF THOMASVILLE INCORPORATED
LITTLETON, CO—2026-07-13 00:00:00
ASPEN EXTERIORS LLC
OXFORD, OH—2026-07-13 00:00:00
R&R SIDING LLC
More inspections in NY
MAYVILLE, NY—2026-07-16 00:00:00
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16 00:00:00
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16 00:00:00
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15 00:00:00
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY