Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CIH PROPERTIES INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CIH PROPERTIES INC in 1140 NORTH CAPITOL ST NW, WASHINGTON, DC 20002 (NAICS 531311). OSHA activity number 339901001.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CIH Properties INC — free Get an email when a new federal OSHA severe-injury report for CIH Properties INC is published. One employer, no account, unsubscribe in one click.
Establishment
CIH PROPERTIES INC
Site address
1140 NORTH CAPITOL ST NW
City
WASHINGTON
State
DC
ZIP
20002
Mailing
1140 NORTH CAPITOL ST NW, WASHINGTON, DC 20002
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
531311
Employees
50
Ownership type
A

6 citations on file for this inspection.

1910.303 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 21, 2014
Abate by
Nov 17, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling      On August 13, 2014 and at times prior thereto; basement; the employer had the employees develop a electrical lighting system by combining lights in a series.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.305 A02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 21, 2014
Abate by
Nov 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(ii): Temporary electrical power and lighting installations over 600 volts, nominal, were used at times other than during periods of tests, experiments, or emergencies:   On August 13, 2014 and at times prior thereto; basement;  the employer had a company developed temporary lighting  system installed which is still active months after the project was completed.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 A02 IX

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 21, 2014
Abate by
Nov 17, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(ix): Lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lamp holder with a guard:  On August 13, 2014 and at times prior thereto; basement;  temporary lighting used in the process did not have the lamps guarded to prevent accidental breakage   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 21, 2014
Abate by
Nov 17, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  On August 13, 2014 and at times prior thereto; basement; electrical panels were blocked by equipment and/or materials such as but not limited to doors used in the facility.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.303 G02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 21, 2014
Abate by
Nov 17, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):   On August 13, 2014 and at times prior thereto; basement; employer had live electrical wiring hanging from the ceiling to the floor exposing employees to a shock hazard.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.305 B02

Serious Gravity 5 5 instances 3 exposed
Issued
Oct 21, 2014
Abate by
Nov 7, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  a) On August 13, 2014 and at times prior thereto; throughout basement floor; the energized conductors to the outlets were not protected from accidental contact exposing the employees to a shock hazard.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800