WASHINGTON, DC ·
OSHA Inspection: 3921 FULTON ST., LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of 3921 FULTON ST., LLC in 3921 FULTON STREET NW, WASHINGTON, DC 20010 (NAICS 238130). OSHA activity number 339901548.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- 3921 FULTON ST., LLC
- Site address
- 3921 FULTON STREET NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20010
- Mailing
- 1345 S STREET NW #1, WASHINGTON, DC 20009
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 18
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B13
- Issued
- Aug 27, 2014
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On August 14, 2014 and at times prior thereto; Rear area of building; employees framing a residential home were observed working on the roof area (outer wall) without a personal fall arrest system in place to prevent them from falling 30 feet to ground level.
Recent events (2)
- · I (S) $1400
- · Z (S) $2800
1926.1053 B01
- Issued
- Aug 27, 2014
- Abate by
- Sep 16, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed On August 14, 2014 and at times prior thereto; Rear area second floor; the ladder used to access the work area (roof) was 18 inches below the working platform exposing them to a fall hazard of 12 feet to ground level while accessing or stepping off the ladder to the platform. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1926.1053 B04
- Issued
- Aug 27, 2014
- Abate by
- Sep 23, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: On June 14, 2014 and at times prior thereto; second floor rear area; employees were using a step ladder in the closed position to access the upper platform/roof of the residential home. Step ladders are designed to be used in the completely open position. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.1053 B13
- Issued
- Aug 27, 2014
- Abate by
- Sep 16, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) On August 14, 2014 and at times prior thereto; Rear area second floor; the step ladder used to access the work area (roof) was 18 inches below the working platform having the employees to use the top step and exposing them to a fall hazard of 12 feet to ground level while accessing or stepping off the ladder to the platform Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 238130)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339901548.