Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SEFCOR, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SEFCOR, INC. in 1150 UNIFORM ROAD, GRIFFIN, GA 30223 (NAICS 335931). OSHA activity number 339902066.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sefcor, INC. — free Get an email when a new federal OSHA severe-injury report for Sefcor, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SEFCOR, INC.
Site address
1150 UNIFORM ROAD
City
GRIFFIN
State
GA
ZIP
30223
Mailing
1150 UNIFORM ROAD, GRIFFIN, GA 30223
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335931
Employees
78
Ownership type
A

5 citations on file for this inspection.

1910.147 C07 I

Serious Gravity 5 1 instance 5 exposed
Issued
Nov 13, 2014
Abate by
Dec 3, 2014
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:  a) At the facility- The employer did not train line support employees performing work on machines and equipment so that they had the knowledge and skills required for the safe application, usage, and removal of energy control.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.178 L04 III

Serious Gravity 5 1 instance 5 exposed
Issued
Nov 13, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years.  a) At the facility: The employer did not conduct an evaluation of the performance of forklift operators at least once every 3 years, exposing employees to struck by hazards.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Nov 13, 2014
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) At Warehouse B- The employer did not provide machine guarding for a 15" Jet Drill Press Bit Model: J-A 3816. The employer did not provide guarding to protect the operator(s) from the hazards of entanglement, rotating parts and amputation hazards.  b) At Warehouse B- The employer did not provide machine guarding for the Jet Geared Head Precision Lathe Model: GH 1860ZX; Serial No:110825ZX2342. The employer did not provide guarding to protect the operator(s) from the hazards of entanglement, rotating parts and amputation hazards.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.303 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 13, 2014
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   a) At Warehouse B Assembly Area-The employer was using an Archer Relocatable Power Tap (RPT) permanently secured to a wood frame with a piece of metal.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.147 C06 I

Other-than-serious 1 instance 5 exposed
Issued
Nov 13, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) Facility- The employer did not conduct a periodic inspection of the energy control procedures, exposing employees to injuries due to not following proper procedures.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Sefcor, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339902066.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.