CALVERT, AL —
OSHA Inspection: OUTOKUMPU STAINLESS USA, LLC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of OUTOKUMPU STAINLESS USA, LLC. in 1 THYSSENKRUPP DRIVE, CALVERT, AL 36513 (NAICS 331111). OSHA activity number 339902462.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OUTOKUMPU STAINLESS USA, LLC.
- Site address
- 1 THYSSENKRUPP DRIVE
- City
- CALVERT
- State
- AL
- ZIP
- 36513
- Mailing
- P.O. BOX 13000, CALVERT, AL 36513
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331111
- Employees
- 910
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 F03 II D
- Issued
- Dec 1, 2014
- Abate by
- Dec 18, 2014
- Penalty
- Initial $3,375 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee shall affix a personal lockout or tagout device to the group lockout device prior to working on the machine or equipment: a) EAF system: On or about June 2, 2014 during the inspection, the employer did not ensure the outside personnel's authorized employees affixed a personal lockout and/or tag out device to the EAF system while conducting contracted services in the dropout chamber.
Recent events (2)
- — I (S) $2000
- — Z (S) $3375
1910.147 F02 I
- Issued
- Dec 1, 2014
- Abate by
- Dec 18, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(f)(2)(i): When outside servicing personnel are to be engaged in activities covered by the scope and application of this standard, the on-site employer and the outside employer did not inform each other of their respective lockout or tagout procedures: a) EAF system: On or about June 2, 2014 During the inspection, the employer and contractor did not inform each other of respective Control of Hazardous Energy (lockout tag out) programs applicable to potential inadvertent startup of the EAF system.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Outokumpu Stainless USA, LLC.
View Outokumpu Stainless USA, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 331111)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339902462.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.