Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: AQ GENERAL CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AQ GENERAL CONSTRUCTION, INC. in 1620 A STREET, SE, WASHINGTON, DC 20007 (NAICS 236116). OSHA activity number 339904088.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AQ General Construction, INC. for free Get an email when a new federal OSHA severe-injury report for AQ General Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1620 A STREET, SE
City
WASHINGTON
State
DC
ZIP
20007
Mailing
3107 UPSHUR STREET, MOUNT RAINIER, MD 20712
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
7
Ownership type
A

7 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 3 instances 7 exposed
Issued
Oct 14, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a) First Floor Entrance - Employees were observed standing near a wall opening that was 6 feet wide and exposed to an 11 foot fall hazard, on or about 08/14/2014.  b) Roof - An employee was observed installing coping on the top of a parapet wall and exposed to a 35 foot fall hazard , on or about 08/14/2014.  c) Second Floor - Employees were observed standing near a stairway opening that was not provided a guardrail and exposed to a 10 feet fall hazard, on or about 08/14/14;
Recent events (1)
  • · Z (S) $2000

1926.503 A01

Serious Gravity 5 1 instance 7 exposed
Issued
Oct 14, 2014
Abate by
Oct 31, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  a) Job Site - Employees were exposed to falls ranging from 10' to 35' and  not provided adequate fall protection training, on or about 08/14/2014.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • · Z (S) $0

1926.1052 C01 I

Serious Gravity 5 1 instance 7 exposed
Issued
Oct 14, 2014
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:  a) Stairways Between Floors - Employees were observed using stairways that had 15 risers and no handrail was provided, on or about 08/14/2014.
Recent events (1)
  • · Z (S) $1600

1926.1052 C01 II

Serious Gravity 5 1 instance 7 exposed
Issued
Oct 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:  a) Stairways Between Floors - Employees were observed using stairways that had 15 risers and no stair rail was provided, on or about 08/14/2014.
Recent events (1)
  • · Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 7 exposed
Issued
Oct 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder:  a) First Floor Entrance - Employees were observed using a wooden job made ladder to gain access to the structure and the side rails only extended 13 inches above the landing surface, on or about 08/14/2014.
Recent events (1)
  • · Z (S) $0

1926.1053 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  a) Second Floor - A foreman was observed standing on an 8 foot portable step ladder that was in the closed position, while nailing wooden framing members, on or about 08/14/14.
Recent events (1)
  • · Z (S) $0

1926.1060 A

Serious Gravity 5 1 instance 7 exposed
Issued
Oct 14, 2014
Abate by
Oct 31, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards:  a) Job Site - Employees were not provided adequate training in the recognition and avoidance of hazards associated with ladder and stairway usage as evidenced by noted hazards such as but not limited to; ladder not properly extended above landing, ladder not used correctly and railings not provided on stairways, on or about 08/14/2014.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339904088.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.