Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALEXANDER JR BUILDING SERVICES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALEXANDER JR BUILDING SERVICES, INC. in 1907 N. BISSELL ST., CHICAGO, IL 60614 (NAICS 238140). OSHA activity number 339904583.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alexander JR Building Services, INC. — free Get an email when a new federal OSHA severe-injury report for Alexander JR Building Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1907 N. BISSELL ST.
City
CHICAGO
State
IL
ZIP
60614
Mailing
643 N. KEDZIE AVE., CHICAGO, IL 60612
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
10
Ownership type
A

7 citations on file for this inspection.

1926.451 D03 III

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 20, 2015
Abate by
Jan 26, 2015
Penalty
Initial $3,080 · Current $1,460 Reduced
29 CFR 1926.451(d)(3)(iii):  Items that were not specifically designed as counterweights were used to counterweight scaffold systems:     a)  Materials not designed to be used as counterweights were used to counterweight a single-point adjustable suspension scaffold system, i.e., boatswains' chair.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1460
  • — Z (S) $3080

1926.451 D05 III

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 20, 2015
Abate by
Jan 26, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.451(d)(5)(iii): Suspension scaffold support devices, such as cornice hooks, roof hooks, roof irons, parapet clamps, or similar devices were not secured against movement by tiebacks installed at right angles to the face of the building or structure and secured to a structurally sound point of anchorage on the building or structure. Sound points of anchorage include structural members, but do not include standpipes, vents, other piping systems, or electrical conduit:  a) Employees were exposed to the hazard of falling while working from a single-point adjustable suspension scaffold, i.e., boatswains' chair, where the support devices were not secured against movement by tiebacks.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F07

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 20, 2015
Abate by
Feb 23, 2015
Penalty
Initial $2,200 · Current $1,020 Reduced
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.     a)  The employer did not ensure that the single-point adjustable scaffolds, i.e., boatswains' chairs, were erected by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection.        In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET)
Recent events (2)
  • — I (S) $1020
  • — Z (S) $2200

1926.451 G03 I

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 20, 2015
Abate by
Jan 26, 2015
Penalty
Initial $3,080 · Current $1,460 Reduced
29 CFR 1926.451(g)(3)(i): Vertical lifelines were not fastened to a fixed safe point of anchorage, independent of the scaffold, and protected from sharp edges and abrasion:      a)  Vertical lifelines that were used by employees working from single-point adjustable suspension scaffold, i.e., boatswains' chair, were not fastened to a fixed safe point of anchorage.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1460
  • — Z (S) $3080

1926.502 D15

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 20, 2015
Abate by
Jan 26, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person:  a)  The employer did not ensure that the anchorage used by employees as an attachment point for personal fall arrest system was capable of supporting at least 5,000 pound per employee attached to it.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01 I

Repeat Gravity 10 1 instance 2 exposed
Issued
Jan 20, 2015
Abate by
Jan 26, 2015
Penalty
Initial $6,160 · Current $3,000 Reduced
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:      a) Employees were exposed to the hazard of falling while working from the boatswains' chair suspended approximately 30 feet above the ground.     Alexander Jr Building Services, Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.451(g)(1)(i), which was contained in OSHA inspection number 856363, citation number 1, item number 1, and was affirmed as a final order on May 30, 2013, with respect to a workplace located at 3764 N. Clark St., Chicago, IL 60613.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (R) $3000
  • — Z (R) $6160

1926.454 A

Repeat Gravity 5 1 instance 2 exposed
Issued
Jan 20, 2015
Abate by
Feb 23, 2015
Penalty
Initial $4,400 · Current $1,100 Reduced
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:    a)  Employer did not provide training to each employee in order to recognize hazards associated with working from boatswains' chair and to understand procedures to control or minimize those hazards.    Alexander Jr Building Services, Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.451(g)(1)(i), which was contained in OSHA inspection number 856363, citation number 1, item number 2, and was affirmed as a final order on May 30, 2013, with respect to a workplace located at 3764 N. Clark St., Chicago, IL 60613.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (R) $1100
  • — Z (R) $4400

View Alexander JR Building Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339904583.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.