POTH, TX —
OSHA Inspection: MANNING SAFETY SERVICES, INC.
Unprogrammed Other inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Other health inspection of MANNING SAFETY SERVICES, INC. in CR 204 7.5 MI. SW OF POTH LYSSEY A #1H WELL, POTH, TX 78147 (NAICS 213112). OSHA activity number 339904690.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MANNING SAFETY SERVICES, INC.
- Site address
- CR 204 7.5 MI. SW OF POTH LYSSEY A #1H WELL
- City
- POTH
- State
- TX
- ZIP
- 78147
- Mailing
- P.O. BOX 502, JOURDANTON, TX 78026
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.132 C
- Issued
- Aug 18, 2014
- Abate by
- Aug 21, 2014
- Penalty
- Initial $2,100 · Current $1,260 Reduced
1480
General-duty citation text
29 CFR 1910.132(c): Personal protective equipment was not of safe design and construction for the work to be performed: and/or in the alternative: 29 CFR 1910.134(d)(1)(ii): The employer did not select and use a NIOSH-certified respirator in compliance with the conditions of its certification: At the drilling site located at Lyssy A-1H well near Poth, Texas, on or about March 12, 2014 and at times prior thereto SKA-PAK escape SCBA / supplied air respirators provided for use by employees of Patterson-UTI Drilling Company LLC Rig 250 in potentially hazardous atmospheres were equipped with polyester head harnesses in lieu of flame resistant Kevlar, exposing employees to the hazards of flash fire. Use of the polyester head harness and nylon waist and shoulder harness configuration is prohibited by manufacturer Scott Safety when exposure to flame or radiant heat is a possibility as the components may melt or burn.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.134 H02 I
- Issued
- Aug 18, 2014
- Abate by
- Aug 21, 2014
- Penalty
- Initial $2,100 · Current $1,260 Reduced
1480
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: At the drilling site located at Lyssy A-1H well near Poth, Texas, on or about March 12, 2014 and at times prior thereto SKA-PAK combination escape SCBA / supplied air respirators provided for employees of Patterson-UTI Drilling Company LLC Rig 250 were stored outside the Driller's Cabin in cases that were not water-tight and air-tight, thereby subjecting components to damage and/or contamination by dust/dirt and moisture. There was rainwater in two of the four Breathing Air cases and the regulator in one of the cases was wet and soiled.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
More inspections at Manning Safety Services, INC.
View Manning Safety Services, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339904690.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.