OSHA Inspection: DANGELO DISTRIBUTORS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DANGELO DISTRIBUTORS, INC. in 1945 STATE ROAD 16, SAINT AUGUSTINE, FL 32084 (NAICS 327991). OSHA activity number 339907172.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dangelo Distributors, INC. — free Get an email when a new federal OSHA severe-injury report for Dangelo Distributors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1945 STATE ROAD 16
City
SAINT AUGUSTINE
State
FL
ZIP
32084
Mailing
1945 STATE ROAD 16, SAINT AUGUSTINE, FL 32084
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327991
Employees
7
Ownership type
A

15 citations on file for this inspection.

1910.37 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 15, 2014
Abate by
Dec 3, 2014
Penalty
Initial $1,200 · Current $730 Reduced

Hazardous substances 21509685

29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":    a. On or about August 19, 2014, the emergency exit at the back side of the fabrication shop was not marked with a sign reading "Exit".
Recent events (2)
  • — I (S) $730
  • — Z (S) $1200

1910.95 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 15, 2014
Abate by
Mar 3, 2015
Penalty
Initial $2,000 · Current $1,290 Reduced

Hazardous substances 8111

29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:     a. On August 19, 2014, an employee fabricating granite counter tops was exposed to a noise dose of 66.5%, or an equivalent dBA (decibels, A scale) of 87.5 dBA.  The sampling was performed on for 186 minutes during one work shift. The employer did not administer a continuing and effective hearing conservation program as describe in paragraph (c) through (o) of the OSHA hearing conservation standard. The employer did not:    1. Develop and implement a monitoring program,  2. Establish and maintain an audiometric testing program,  3. Institute a training program with the requirements of this section, and  4. Have available for the employees a copy of OSHA hearing conservation standard.
Recent events (2)
  • — I (S) $1290
  • — Z (S) $2000

1910.178 L01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 15, 2014
Abate by
Dec 3, 2014
Penalty
Initial $1,200 · Current $730 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    a. On or about August 19, 2014, the employer did not train and evaluate each operator who is authorized to operate the Yale powered industrial truck to ensure they were competent to operate it safely.
Recent events (2)
  • — I (S) $730
  • — Z (S) $1200

1910.242 B

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 15, 2014
Abate by
Nov 10, 2014
Penalty
Initial $1,600 · Current $990 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    a. On or about August 19, 2014, employees were exposed to being struck-by debris while blowing air into the granite slabs after cutting a sink hole or clearing their clothing from dust throughout the shift because the air pressure was not reduced to less than 30 psi.
Recent events (2)
  • — I (S) $990
  • — Z (S) $1600

1910.243 C01

Serious Gravity 10 2 instances 3 exposed
Issued
Oct 15, 2014
Abate by
Nov 10, 2014
Penalty
Initial $2,800 · Current $1,840 Reduced
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4):    a. On or about August 19, 2014, an employee was using a hand held portable grinder with a 6-inches diamond blade to cut sink holes on the granite counter tops without a safety guard, exposing the employees to amputation hazards.
Recent events (2)
  • — I (S) $1840
  • — Z (S) $2800

1910.303 F02

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 15, 2014
Abate by
Nov 10, 2014
Penalty
Initial $1,200 · Current $730 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    a. On or about August 19, 2014, in the fabrication shop, circuit breakers #2, 3, 5, 6, 7, and 8 on the distribution panel were not marked to indicate their purpose, exposing employees to electrical shock hazards.
Recent events (2)
  • — I (S) $730
  • — Z (S) $1200

1910.1000 C

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 15, 2014
Abate by
Mar 3, 2015
Penalty
Initial $2,800 · Current $1,850 Reduced

Hazardous substances 9010

29 CFR 1910.1000(c): Employees were exposed to respirable crystalline silica (Quartz), listed in Table Z-3, in excess of 10 milligrams per meter cubed / % SiO2 + 2 as an 8-hour time-weighted average concentration (TWA):    a. On or around August 20, 2014, an employee working as a fabricator was exposed to silica crystalline quartz, respirable fraction, at an 8-hour Time Weighted Average (TWA) of 1.35 milligrams per cubic meter, approximately 1.20 times the limit of 1.12 milligrams per cubic meter while fabricating granite counter tops.  The sampling was performed for 185 minutes during one shift.  Zero exposure was assumed for the remainder time not sampled.
Recent events (2)
  • — I (S) $1850
  • — Z (S) $2800

1910.1000 E

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 15, 2014
Abate by
Mar 3, 2015
Penalty
Initial $0 · Current $0

Hazardous substances 9010

29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):  a. On or around August 20, 2014, an employee working as a fabricator was exposed to silica crystalline quartz, respirable fraction, at an 8-hour Time Weighted Average (TWA) of 1.35 milligrams per cubic meter, approximately 1.20 times the limit of 1.12 milligrams per cubic meter while fabricating granite counter tops.  The sampling was performed for 185 minutes during one shift.  Zero exposure was assumed for the remainder time not sampled.  The employer did not determined or implemented feasible administrative or engineering controls to achieve keep silica exposure levels below OSHA permissible limits.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 15, 2014
Abate by
Mar 3, 2015
Penalty
Initial $0 · Current $0

Hazardous substances 9010

29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use:  a. On or around August 20, 2014, an employee working as a fabricator was exposed to silica crystalline quartz, respirable fraction, at an 8-hour Time Weighted Average (TWA) of 1.35 milligrams per cubic meter, approximately 1.20 times the limit of 1.12 milligrams per cubic meter while fabricating granite counter tops.  The sampling was performed for 185 minutes during one shift.  Zero exposure was assumed for the remainder time not sampled.  The employer did not developed or implemented a written respiratory protection program with work-site specific procedures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 15, 2014
Abate by
Dec 3, 2014
Penalty
Initial $2,800 · Current $1,840 Reduced

Hazardous substances 215090109685

29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a.  On or about August 19, 2014, fabricators worked with flammable chemicals such as, acetone, propane cylinders, thinners, bonding agents, color enhancers, and multipurpose adhesives while fabricating granite counter tops.  The employees were also exposed to respirable silica dust and the employer had not developed, implemented, or maintained at the workplace a written hazard communication program that described how the requirements for labels and other form of markings, safety data sheets, and training will be met.
Recent events (2)
  • — I (S) $1840
  • — Z (S) $2800

1910.1200 G01

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 15, 2014
Abate by
Dec 3, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 215090109685

29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use:  a.  On or about August 19, 2014, fabricators worked with flammable chemicals such as, acetone, propane cylinders, thinners, bonding agents, color enhancers, and multipurpose adhesives while fabricating granite counter tops.  The employees were exposed to respirable silica dust and the employer did not have the safety data sheet for each hazardous chemical used.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 15, 2014
Abate by
Dec 3, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 215090109685

29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a.  On or about August 19, 2014, fabricators worked with flammable chemicals such as, acetone, propane cylinders, thinners, bonding agents, color enhancers, and multipurpose adhesives while fabricating granite counter tops.  The employees were exposed to respirable silica dust and the employer had not provided effective information and training on the health and physical hazards of the chemicals being used at their initial assignment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H03 IV

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 15, 2014
Abate by
Dec 3, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 215090109685

29 CFR 1910.1200(h)(3)(iv):   The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information:  a.  On or about August 19, 2014, fabricators worked with flammable chemicals such as, acetone, propane cylinders, thinners, bonding agents, color enhancers, and multipurpose adhesives while fabricating granite counter tops and the employer did not explained the new labeling system and safety data sheet required under the new hazard communication program (GHS 2012).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 E03

Other-than-serious 2 instances 4 exposed
Issued
Oct 15, 2014
Abate by
Dec 3, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 21509685

29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  a. On or about August 19, 2014, employees used highly flammable chemicals during the fabrication of granite counter tops and there were three ABC type portable fire extinguishers at the fabrication shop that were not subjected to annual maintenance check. The last annual maintenance check was completed about May 2010.   b. On or about August 19, 2014, there was a ABC type portable fire extinguisher that was not subjected to annual maintenance check.  the last annual maintenance check was completed about September 2010.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 2 instances 3 exposed
Issued
Oct 15, 2014
Abate by
Nov 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  a.  On or about August 19, 2014, at the back of the fabrication shop, the flexible cord connected to the four-gang electrical box attached to the work bench was not connected to device and fitting so that strain relief was provided.  b. On or about August 19, 2014, at the fabrication shop, the flexible cords connected to the CNC machine were not connected to device and fittings so that strain relief was provided.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Dangelo Distributors, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339907172.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.