WAUKESHA, WI —
OSHA Inspection: SJS CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SJS CONSTRUCTION, INC. in 516 ARBOR OAKS LANE, WAUKESHA, WI 53188 (NAICS 238160). OSHA activity number 339911414.
Where did this inspection happen?
- Establishment
- SJS CONSTRUCTION, INC.
- Site address
- 516 ARBOR OAKS LANE
- City
- WAUKESHA
- State
- WI
- ZIP
- 53188
- Mailing
- 9731 SOUTH BLUEGRASS PLACE, OAK CREEK, WI 53154
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. (a) The employer did not ensure that eye protection was used when using nail guns, exposing employees to struck-by hazards.
Recent events (2)
- — I (S) $1000
- — Z (S) $1600
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. a) Employer did not ensure that employees had adequate access and egress of the ladder jack scaffolding system.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.451 E08
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(e)(8): Direct access to or from another surface was used when the scaffold was more than 14 inches (36 cm) horizontally and/or 24 inches (61 cm) vertically from the other surface: (a) The employer did not ensure proper access was used where a break in elevation existed between the platform of a ladder jack scaffold and roof surface, exposing employees to fall hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B10
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(10): The tops of a non-self-supporting ladder were not placed with the two rails supported equally: (a) The employer did not ensure that the top rails of a ladder were resting equally on the landing surface, exposing employees to fall hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1926.452 K01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.452(k)(1): Platforms exceeded a height of 20 feet (6.1 m): (a) The employer did not ensure that the height of a ladder jack scaffold platform did not exceed 20 feet, exposing employees to fall hazards.
Recent events (2)
- — I (S) $2000
- — Z (S) $2000
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) The employer did not ensure that employees were using fall protection when conducting roofing work. The employees were exposed to falling up to 24.3 feet to the ground below.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.552 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.552(a)(1): 29 CFR 1926.552(a)(1): The employer did not comply with the manufacturer's specifications and limitations applicable to the operation of all hoists and elevators. (a) The employer did not ensure that the manufacturer's specifications were followed for a RGC hoisting device. The employees used the hoisting track as a ladder, exposing them to a fall hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at SJS CONSTRUCTION, INC.
HUNTINGTON STATION, NY—2015-01-05 00:00:00
SJS CONSTRUCTION INC.
RENO, NV—2011-09-27 00:00:00
SJS CONSTRUCTION, INC.
FRANKLIN, WI—2008-05-06 00:00:00
SJS CONSTRUCTION, INC.
View SJS CONSTRUCTION, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339911414.