Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: RAYCO PUMPING UNIT SERVICE

Fatality or catastrophe inspection · Safety discipline

On , OSHA opened a fatality or catastrophe safety inspection of RAYCO PUMPING UNIT SERVICE in TURNER GREGORY UNIT WELL 1001, COLORADO CITY, TX 79512 (NAICS 238990). OSHA activity number 339913196.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rayco Pumping Unit Service for free Get an email when a new federal OSHA severe-injury report for Rayco Pumping Unit Service is published. One employer, no account, unsubscribe in one click.
Site address
TURNER GREGORY UNIT WELL 1001
City
COLORADO CITY
State
TX
ZIP
79512
Mailing
3703 S. COUNTY RD. 1198, MIDLAND, TX 79706
Inspection type
Fatality or catastrophe (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
5
Ownership type
Private (A)

3 citations on file for this inspection.

1910.333 C03 I B

Serious Gravity 10 1 instance 4 exposed
Issued
Oct 21, 2014
Abate by
Oct 27, 2014
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.333(c)(3)(i)(B): When an unqualified person is working on the ground in the vicinity of overhead lines, the person may not bring any conductive object closer to unguarded, energized lines than the distance given in paragraph (c)(3)(i)(A) of this section.    On or about August 20, 2014 the employer did not ensure that conductive objects were not allowed to come into contact with overhead power lines at the well site exposing employees to electrical hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $7000

1910.333 C03 III A

Serious Gravity 10 1 instance 4 exposed
Issued
Oct 21, 2014
Abate by
Oct 27, 2014
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.333(c)(3)(iii)(A): Vehicles or mechanical equipment capable of having parts of their structures elevated near energized overhead lines were not operated so that a clearance of 10 feet (305 cm) was maintained.    On or about August 20, 2014 the employer did not ensure that a pole truck was operated so that a minimum of ten feet was maintained from overhead power lines at the well site exposing employees to electrical hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $7000

1910.333 C03 III B

Serious Gravity 10 1 instance 4 exposed
Issued
Oct 21, 2014
Abate by
Oct 27, 2014
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.333(c)(3)(iii)(B): Employees standing on the ground may not contact the vehicle or mechanical equipment.    On or about August 20, 2014 the employer did not ensure that employees did  not come into contact with a pole truck that was being operated in close proximity to overhead power lines at the well site exposing employees to electrical hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $7000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339913196.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.