MANITOWOC, WI ·
OSHA Inspection: ALL GUTTERS LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of ALL GUTTERS LLC in 846 SUMMIT AVE, MANITOWOC, WI 54220 (NAICS 238160). OSHA activity number 339913774.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALL GUTTERS LLC
- Site address
- 846 SUMMIT AVE
- City
- MANITOWOC
- State
- WI
- ZIP
- 54220
- Mailing
- 1055 SILVER LAKE RD., PORTAGE, WI 53901
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 12
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Sep 17, 2014
- Penalty
- Initial $2,400 · Current $1,680 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On 8/21/14, employees reroofing a house and a detached garage were not using any form of fall protection.
Recent events (2)
- · I (S) $1680
- · Z (S) $2400
1926.1053 B01
- Issued
- Sep 17, 2014
- Penalty
- Initial $1,600 · Current $1,120 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On 8/21/14, the Foreman used an 8' step ladder to access the roof of the house that had eaves 8' above the wood deck.
Recent events (2)
- · I (S) $1120
- · Z (S) $1600
1926.1053 B13
- Issued
- Sep 17, 2014
- Abate by
- Sep 25, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: On 8/21/14, the Foreman stepped off the roof onto the head of the step ladder and then turned to step down and stand on the top step of the ladder.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at ALL Gutters LLC
View ALL Gutters LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339913774.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.