DOWNSVILLE, WI ·
OSHA Inspection: ADVANTAGE COATING INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ADVANTAGE COATING INC. in N2681 460TH STREET, DOWNSVILLE, WI 54735 (NAICS 238390). OSHA activity number 339913873.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANTAGE COATING INC.
- Site address
- N2681 460TH STREET
- City
- DOWNSVILLE
- State
- WI
- ZIP
- 54735
- Mailing
- 884 ARBOR DR, CHASKA, MN 55318
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238390
- Employees
- 18
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.134 C01
- Issued
- Feb 10, 2015
- Abate by
- Mar 11, 2015
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) Downsville school remodeling project; The employer did not develop and implement a written respiratory protection program for employees that were working with shot blast material that contained iron, manganese, silicon, chromium, copper and nickel.
Recent events (2)
- · I (S) $1960
- · Z (S) $2800
1926.416 E01
- Issued
- Feb 10, 2015
- Abate by
- Feb 23, 2015
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) Downsville school remodeling project: The electrical cords that powered the vacuum and the shot blaster were damaged and not taken out of service.
Recent events (2)
- · I (S) $1960
- · Z (S) $2800
More inspections at Advantage Coating INC.
View Advantage Coating INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238390)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339913873.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.