Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SILVA & ASSOCIATES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SILVA & ASSOCIATES in 303 COPELAND AVENUE, LYNDHURST, NJ 07071 (NAICS 238140). OSHA activity number 339914665.

Watch Silva & Associates — free Get an email when a new federal OSHA severe-injury report for Silva & Associates is published. One employer, no account, unsubscribe in one click.
Establishment
SILVA & ASSOCIATES
Site address
303 COPELAND AVENUE
City
LYNDHURST
State
NJ
ZIP
07071
Mailing
47 SOUTH WILLOW STREET, MONTCLAIR, NJ 07042
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
A

7 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2400.00 · Current $2400.00
29 CFR 1926.100(a):   Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:   A) Ground, front of house: - Employees were exposed to head injuries while working below roofing/stucco activities. The employees were not protected by hard hats or protective helmets, on or about August 12th, 2014.
Recent events (1)
  • — Z (S) $2400

1926.416 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:    A) Roof of house: An employee was exposed to electrocution hazards while working within 1 foot of energized, un-insulated electrical wires on or about August 12th, 2014.
Recent events (1)
  • — Z (S) $2800

1926.451 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(b)(1):   Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports:   A) On Scaffold : Employees were exposed to fall hazards of approximately 14 and 17 feet while working on a fabricated framed scaffold that was not fully planked, on or about August 12th, 2014.
Recent events (1)
  • — Z (S) $2800

1926.451 C02 II

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(c)(2)(ii): Unstable objects shall not be used to support scaffolds or platform units.  A) Roof of house:  An employee was exposed to fall/scaffold collapse hazards of approximately 17 feet while working on a fabricated framed scaffold that was not erected on firm foundation, on or about August 12th, 2014.
Recent events (1)
  • — Z (S) $2800

1926.451 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used.      A) On Scaffold - Employees were exposed to fall hazards of approximately 12 feet while working on a fabricated framed scaffold that was not provided with safe access, on or about August 12th, 2014.
Recent events (1)
  • — Z (S) $2000

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(g)(1):   Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.   A) Scaffold/Front of house - An employee was exposed to fall hazards of approximately 14 feet while working on a fabricated framed scaffold that was not protected by a complete guardrail system or there means of fall protection in place, on or about August 12th, 2014.
Recent events (1)
  • — Z (S) $2800

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(13):   Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b)   A) Roof: Employees were exposed to fall hazards of approximately 14 feet while engaged in roofing work on a residential structure without a means of fall protection in place, on or about August 12th, 2014.
Recent events (1)
  • — Z (S) $2800