Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: TEVA PHARMACEUTICALS USA, INC. DBA BARR LABORATORIES, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of TEVA PHARMACEUTICALS USA, INC. DBA BARR LABORATORIES, INC. in 223 QUAKER ROAD, POMONA, NY 10970 (NAICS 325412). OSHA activity number 339914780.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Teva Pharmaceuticals USA, INC. DBA Barr Laboratories, INC. for free Get an email when a new federal OSHA severe-injury report for Teva Pharmaceuticals USA, INC. DBA Barr Laboratories, INC. is published. One employer, no account, unsubscribe in one click.
Site address
223 QUAKER ROAD
City
POMONA
State
NY
ZIP
10970
Mailing
223 QUAKER ROAD, POMONA, NY 10970
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325412
Employees
300
Ownership type
Private (A)

2 citations on file for this inspection.

1910.133 A01

Serious Gravity 5 3 instances 30 exposed
Issued
Sep 5, 2014
Abate by
Oct 23, 2014
Penalty
Initial $4,250 · Current $3,500 Reduced
29 CFR 1910.133(a)(1): Protective eye and/or face equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:    a)  Laboratory 1005:  An employee heating a potassium cyanide solution was exposed to potassium cyanide that reacted by violently erupting out of a beaker and hitting the employee in the face and mouth.   The employee was not required to wear appropriate eye and face protection (e.g., chemical splash goggles and face shield) when performing this procedure; on or about 7/8/14.     b) Laboratory 1005 - Walk-In Hood:  Employees dispensed acetonitrile and methanol and were not required to wear appropriate eye protection (e.g.,  chemical splash goggles or equivalent) ; on or about 7/10/14.    c) Laboratory 1005:  Employees who poured and dispensed various hazardous chemicals, including but not limited to acetonitrile, methanol, 0.1N hydrochloric acid solutions, etc. were not required to wear appropriate eye protection (e.g., chemical splash goggles or equivalent); on or about 7/10/14.
Recent events (2)
  • · I (S) $3500
  • · Z (S) $4250

1910.1450 E03 I

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Sep 5, 2014
Abate by
Oct 10, 2014
Penalty
Initial $4,250 · Current $0 Reduced
29 CFR 1910.1450(e)(3)(i): The employer's Chemical Hygiene Plan did not include the standard operating procedures relevant to safety and health considerations to be followed when laboratory work involved the use of hazardous chemicals:  a) Laboratory 1005:   The chemical hygiene plan did not include standard operating procedures for applying heat to potassium cyanide solutions and the potential hazards associated with this process; on or about 7/8/14.
Recent events (2)
  • · I (S) $0
  • · Z (S) $4250

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339914780.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.