PHILADELPHIA, PA ·
OSHA Inspection: BLUE MOUNTAIN RECYCLING, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BLUE MOUNTAIN RECYCLING, LLC in 2904 ELLSWORTH STREET, PHILADELPHIA, PA 19146 (NAICS 423930). OSHA activity number 339916751.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BLUE MOUNTAIN RECYCLING, LLC
- Site address
- 2904 ELLSWORTH STREET
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19146
- Mailing
- 2904 ELLSWORTH STREET, PHILADELPHIA, PA 19146
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 95
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1910.23 C03
- Issued
- Feb 13, 2015
- Abate by
- Feb 24, 2015
- Penalty
- Initial $2,100 · Current $2,100
General-duty citation text
29 CFR 1910.23(c)(3): Regardless of height, open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment, pickling or galvanizing tanks, degreasing units, and similar hazards were not guarded with a standard railing and toe board. a) Jobsite: Plastic Sorting Station #416 - Employees were conducting recycling activities from a platform that was missing a midrail. The platform was located next to a moving conveyor, on about 8/22/14.
Recent events (2)
- · I (O) $2100
- · Z (S) $2100
1910.27 B01 II
- Issued
- Feb 13, 2015
- Abate by
- Feb 26, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.27(b)(1)(ii): The distance between rungs exceeded 12 inches and were not uniform throughout the ladder: a) Jobsite: Plastic Sorting Station #416 - Employees who conduct recycling activities access the work station from a fixed ladder with rungs that exceeded 12 inches and were not uniform, on or about 8/22/14.
Recent events (2)
- · I (O) $2800
- · Z (S) $2800
1910.134 F01
- Issued
- Feb 13, 2015
- Abate by
- Jun 4, 2015
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment: a) Jobsite: #3 Sort Station - The employer did not select the appropriate personal protective equipment to protect employees from cuts and/or amputation hazards while sorting recycled materials, observed on or about 8/22/15.
Recent events (2)
- · I (O) $4900
- · Z (S) $4900
1910.219 C04 I
- Issued
- Feb 13, 2015
- Abate by
- Feb 20, 2015
- Penalty
- Initial $2,100 · Current $2,100
General-duty citation text
29 CFR 1910.219(c)(4)(i): Shaft ends projecting more than one-half the diameter of the shaft were not guarded by nonrotating caps or safety sleeves. a) Jobsite: Sort Station #3 conveyor - The unprotected and exposed shaft rotating approximately 3 to 4 feet from the ground was not enclosed thus exposing employees to entanglement and amputation hazards, on or about 8/22/14.
Recent events (2)
- · I (O) $2100
- · Z (S) $2100
1910.305 G01 IV A
- Issued
- Feb 13, 2015
- Abate by
- Feb 20, 2015
- Penalty
- Initial $2,100 · Current $2,100
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. a) Jobsite: Aluminum Sorting Station - The flexible cord providing power to the water cooler was used as a substitute for the fixed wiring of a structure exposing employees to electrical and fire hazards, on or about 8/22/14.
Recent events (2)
- · I (O) $2100
- · Z (S) $2100
1910.303 B02
- Issued
- Feb 13, 2015
- Abate by
- Feb 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling. a) Jobsite: Final Sort Station - The employer did not install and use the flexible cord in accordance with the instructions included in the listing or labeling, on or about 8/22/14.
Recent events (2)
- · I (O) $0
- · Z (S) $0
1910.303 B01
- Issued
- Feb 13, 2015
- Abate by
- Feb 20, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: a) Jobsite: Staircase leading to Plastic Sorting Station #416 - A broken ground prong was found inside an outlet exposing the employees to electrical hazards, on or about 8/22/14.
Recent events (2)
- · I (O) $2800
- · Z (S) $2800
More inspections in this industry (NAICS 423930)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339916751.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.