SUPERIOR, CO —
OSHA Inspection: PEREZ ROOFING LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PEREZ ROOFING LLC in 2910 JADE COURT, SUPERIOR, CO 80027 (NAICS 238160). OSHA activity number 339918237.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PEREZ ROOFING LLC
- Site address
- 2910 JADE COURT
- City
- SUPERIOR
- State
- CO
- ZIP
- 80027
- Mailing
- 4453 LIPAN STREET, DENVER, CO 80211
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B13
- Issued
- Aug 27, 2014
- Abate by
- Sep 17, 2014
- Penalty
- Initial $1,360 · Current $1,360
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or another provision in paragraph (b) of this section which provides for an alternative fall protection measure: (a) Perez Roofing LLC, at 2910 Jade Court, Superior, CO: On and before 8/21/14, the employer did not ensure that each employee engaged in residential construction activities 6 feet or more above lower levels was protected by guardrail systems, safety net systems, personal fall arrest systems, or another provision in paragraph (b) of this section which provides for an alternative fall protection measure. Three employees were re-roofing a two story home. The employees were working upon the roof of the second story. This condition exposed the employees to a fall hazard of approximately twenty-one feet.
Recent events (1)
- — Z (S) $1360
1926.503 A01
- Issued
- Aug 27, 2014
- Abate by
- Sep 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program enabling recognition of and appropriate protective procedures for fall hazards for each employee who might be exposed to fall hazards: (a)Perez Roofing LLC, at 2910 Jade Court, Superior, CO: On and before 8/21/14, the employer did not provide a training program enabling recognition of and appropriate protective procedures for fall hazards for each employee who might be exposed to fall hazards. Three employees were re-roofing a two story home. The employees were working upon the roof of the second story. The employees had not been provided fall protection training. This condition exposed the employees to a fall hazard of approximately twenty-one feet.
Recent events (1)
- — Z (S) $0
1926.1053 B01
- Issued
- Aug 27, 2014
- Abate by
- Sep 17, 2014
- Penalty
- Initial $1,360 · Current $1,360
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a)Perez Roofing LLC, at 2910 Jade Court, Superior, CO: On and before 8/21/14, the employer did not ensure portable ladders used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access. Three employees were re-roofing a two story home. The employees accessed the first story roof via an aluminum ladder. The side rails of the ladder extended approximately 1.5 feet above the upper landing surface. This condition exposed the employees to a fall hazard of approximately nine feet.
Recent events (1)
- — Z (S) $1360
1926.1053 B08
- Issued
- Aug 27, 2014
- Abate by
- Sep 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder: (a)Perez Roofing LLC, at 2910 Jade Court, Superior, CO: On and before 8/21/14, the employer did not ensure that ladders placed in a location where they could be displaced by workplace activities were secured to prevent accidental displacement. Three employees were re-roofing a two story home. The employees accessed the second story roof from the sloped first story roof via an aluminum ladder. This condition exposed the employees to a fall hazard of approximately twenty one feet.
Recent events (1)
- — Z (S) $0
More inspections at Perez Roofing LLC
View Perez Roofing LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339918237.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.