Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: M G BUILDING MATERIALS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of M G BUILDING MATERIALS in 4825 RITTIMAN RD., SAN ANTONIO, TX 78218 (NAICS 321113). OSHA activity number 339918716.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M G Building Materials for free Get an email when a new federal OSHA severe-injury report for M G Building Materials is published. One employer, no account, unsubscribe in one click.
Site address
4825 RITTIMAN RD.
City
SAN ANTONIO
State
TX
ZIP
78218
Mailing
2651 S.W. MILITARY DR, SAN ANTONIO, TX 78224
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
75
Ownership type
Private (A)

5 citations on file for this inspection.

1910.176 B

Serious Gravity 10 2 instances 75 exposed
Issued
Jan 16, 2015
Abate by
Jan 27, 2015
Penalty
Initial $7,000 · Current $4,200 Reduced
29 CFR 1910.176(b): Storage of material created a hazard:  (a) Center of shop area: On or about August 22, 2014, and at times prior thereto, employees were exposed to a struck-by and/or crushing hazard while vertically stacking and removed trim boards that were stored on a wood A frame rack.  (b) Center of shop area: On or about August 22, 2014, and times prior thereto, employees were exposed to struck-by hazards while stacking and removing trim boards horizontally that were left loosely on the top of the stack.
Recent events (2)
  • · I (S) $4200
  • · Z (S) $7000

1910.242 B

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 16, 2015
Penalty
Initial $4,400 · Current $2,640 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  Eagle Machine located East side of shop: On or about November 6, 2014, and at times prior thereto, an employee was exposed to a struck-by hazard while using compressed air that was not reduced to less than 30 P.S.I. to clean off machine.
Recent events (2)
  • · I (S) $2640
  • · Z (S) $4400

1910.303 G01 II

Serious Gravity 1 1 instance 75 exposed
Issued
Jan 16, 2015
Penalty
Initial $3,300 · Current $1,980 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  East side of shop: On or about August 22, 2014, and at times prior there to, employees were exposed to delayed access to electrical equipment from items such as trim boards leaned in front of the panel that could interfere with ready access in the event of an emergency.
Recent events (2)
  • · I (S) $1980
  • · Z (S) $3300

1910.305 B01 II

Serious Gravity 10 2 instances 75 exposed
Issued
Jan 16, 2015
Abate by
Jan 27, 2015
Penalty
Initial $7,000 · Current $4,200 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  (a) East side of shop area, 220 Volt/ 100 Amp panel: On or about August 22, 2014, and at times prior thereto, employees were exposed to electrical shock hazards from an open electrical knockout measuring approximately 1" on an electrical panel, while switching on and off the shop lights.  (b) Northeast side of shop area, 220 Volt/ 100 Amp panel: On or about August 22, 2014, and at times prior thereto, employees were exposed to electrical shock hazards from an open electrical knockout measuring approximately 1" on an electrical panel, while switching on and off the shop lights.
Recent events (2)
  • · I (S) $4200
  • · Z (S) $7000

1910.178 L06

Other-than-serious 1 instance 75 exposed
Issued
Jan 16, 2015
Abate by
Feb 21, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  Shop area: On or about August 22, 2014, and at times prior thereto, employees were exposed to struck by hazards from Industrial powered trucks: Yale forklift, Type LP, #F208586 having operators that were trained but not certified.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339918716.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.