CHANNELVIEW, TX ·
OSHA Inspection: SOCOTHERM GULF OF MEXICO LLC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of SOCOTHERM GULF OF MEXICO LLC in 817 SHIELDS ST., CHANNELVIEW, TX 77530 (NAICS 332812). OSHA activity number 339919219.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOCOTHERM GULF OF MEXICO LLC
- Site address
- 817 SHIELDS ST.
- City
- CHANNELVIEW
- State
- TX
- ZIP
- 77530
- Mailing
- 817 SHIELDS ST., CHANNELVIEW, TX 77530
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 250
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 D03
- Issued
- Oct 21, 2014
- Abate by
- Nov 7, 2014
- Penalty
- Initial $6,300 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): The employer does not ensure that all energy isolating devices needed to control the energy to the machine or equipment are physically located and operated in such a manner as to isolate the machine or equipment from the energy sources. a) This violation occurred on or about August 21, 2014 and times prior thereto, in the ID Plant - Inbound Operator Control Panel where employees were exposed to struck-by and/or caught-in hazards when servicing and cleaning internal blasting equipment without all energy isolating devices needed to control energy to the machine or equipment being physically located and operated in a manner to the isolate the equipment from energy sources. b) This violation occurred on or about August 21, 2014 and times prior thereto, in the ID Plant - Blaster Operator Control Panel where employees were exposed to struck-by and/or caught-in hazards when servicing and cleaning internal blasting equipment without all energy isolating devices needed to control energy to the machine or equipment being physically located and operated in a manner to the isolate the equipment from energy sources. c) This violation occurred on or about August 21, 2014 and times prior thereto, in the ID Plant - Outbound Operator Control where employees were exposed to struck-by and/or caught-in hazards when servicing and cleaning internal blasting equipment without all energy isolating devices needed to control energy to the machine or equipment being physically located and operated in a manner to the isolate the equipment from energy sources. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is needed to control the energy to the machine or equipment are physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s).
Recent events (2)
- · I (O) $5000
- · Z (S) $6300
1910.212 A02
- Issued
- Oct 21, 2014
- Abate by
- Aug 6, 2015
- Penalty
- Initial $14,000 · Current $7,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: This violation occurred on or about August 21, 2014 and times prior thereto, where in employees in the ID Plant were exposed to caught-in and struck-by hazards when operating a Bauhuis Internal Blasting and Coating Line without guards affixed or secured elsewhere when attachment to the machine was not possible. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that guard(s) on machine(s) are affixed to the machine or secured elsewhere when attachment to the machine is not possible. Shawcor Ltd. [Parent Company of Socotherm Gulf of Mexico, LLC and ShawCor Pipe Protection, LLC] was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 316277615, citation number 01 item number 001 and was affirmed as a final order on April 5, 2012, with a final abatement date of May 21, 2012, with respect to a workplace located at 3705 N. Frazier, Conroe, TX 77303.
Recent events (3)
- · R (S) $7000
- · C (R) $14000
- · Z (R) $14000
More inspections at Socotherm Gulf of Mexico LLC
View Socotherm Gulf of Mexico LLC's full OSHA safety record →
More inspections in this industry (NAICS 332812)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339919219.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.