Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CK ELECTRIC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CK ELECTRIC in TWO STORY SINGLE FAMILY HOUSE PROJECT ROBLES ROAD, PALA, CA 92059 (NAICS 238210). OSHA activity number 339920407.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CK Electric — free Get an email when a new federal OSHA severe-injury report for CK Electric is published. One employer, no account, unsubscribe in one click.
Establishment
CK ELECTRIC
Site address
TWO STORY SINGLE FAMILY HOUSE PROJECT ROBLES ROAD
City
PALA
State
CA
ZIP
92059
Mailing
PO BOX 2026, VALLEY CENTER, CA 92082
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 5, 2014
Abate by
Nov 14, 2014
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure:  Located at a housing project on Robles Road, Pala, CA 92059, on the north side of the second level balcony, front exterior of the house, there were no guardrails or other means of fall protection exposing employees to hazards associated with fall from heights.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.502 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 5, 2014
Abate by
Nov 14, 2014
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high:  Located at a housing project on Robles Road, Pala, CA 92059, near the west end of a second level hallway, there was no midrail or equivalent for about 40 inches between the top of the stairway and an interior south wall, exposing employees to hazards associated with fall from heights.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.1052 C01 II

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 5, 2014
Abate by
Nov 14, 2014
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with one stairrail system along each unprotected side or edge:  Located at a housing project on Robles Road, Pala, CA 92059, near the west side of the first level, there were no stairrail systems on the unprotected edges of a stairway with six risers to the first landing, five risers to the second landing, and six risers to the second level exposing employees to hazards associated with fall from heights.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339920407.