KANSAS CITY, MO —
OSHA Inspection: RAIN PROOF ROOFING LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RAIN PROOF ROOFING LLC in 105 E 125 TER, KANSAS CITY, MO 64145 (NAICS 238160). OSHA activity number 339923005.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAIN PROOF ROOFING LLC
- Site address
- 105 E 125 TER
- City
- KANSAS CITY
- State
- MO
- ZIP
- 64145
- Mailing
- 8141 RHINEHART RD, KANSAS CITY, MO 64139
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Sep 17, 2014
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On or about August 26, 2014 at worksite 105 E 125 Ter, Kansas City, Missouri.-employees were exposed to a fall hazard when performing roofing activities at an elevation of approximately 22 feet , without an approved form of fall protection, to include, guardrail systems, safety net systems, or personal fall arrest systems
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.1053 B01
- Issued
- Sep 17, 2014
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On or about August 26,2014 at worksite 105 E 125 Ter, Kansas City Missouri.-employees were exposed to a fall hazard by using a ladder which did not extend 3 feet above the landing surface of the roof to which they gained access. Abatement certification for this violation is not required.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
More inspections at Rain Proof Roofing LLC
View Rain Proof Roofing LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339923005.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.