Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: WASTE PRO OF FLORIDA, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WASTE PRO OF FLORIDA, INC. in 7921 15TH STREET EAST, SARASOTA, FL 34243 (NAICS 562111). OSHA activity number 339924987.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Waste PRO of Florida, INC. for free Get an email when a new federal OSHA severe-injury report for Waste PRO of Florida, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7921 15TH STREET EAST
City
SARASOTA
State
FL
ZIP
34243
Mailing
2101 WEST STATE ROAD 434, LONGWOOD, FL 32779
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562111
Employees
90
Ownership type
Private (A)

5 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 3, 2014
Abate by
Sep 22, 2014
Penalty
Initial $3,750 · Current $2,250 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a. Welding shop area, employees were exposed to a struck-by hazard, in that, a guard was not provided on the unused portion of the blade of a Jet horizontal band saw, on or about 08/26/2014.
Recent events (2)
  • · I (S) $2250
  • · Z (S) $3750

1910.253 E03 II C 2

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 3, 2014
Abate by
Sep 9, 2014
Penalty
Initial $2,250 · Current $1,350 Reduced
29 CFR 1910.253(e)(3)(ii)(C)(2): Backflow protection was not provided by an approved device that would prevent oxygen from flowing into the fuel gas system or fuel from flowing into the oxygen system:   a. At the maintenance shop, employees were exposed to a fire hazard, in that, the oxygen and acetylene torch and hoses used during maintenance activities were not equipped with a backflow prevention valve, on or about 08/26/2014.
Recent events (2)
  • · I (S) $1350
  • · Z (S) $2250

1910.253 E03 II C 3

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 3, 2014
Abate by
Sep 9, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.253(e)(3)(ii)(C)(3):  Flashback protection was not provided by an approved device that would prevent flame from passing into the fuel gas system:   a. At the maintenance shop, employees were exposed to a fire hazard, in that, the oxygen and acetylene torch and hoses used during maintenance activities were not equipped with a flashback arrestor, on or about 08/26/2014.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.303 G01 II

Other-than-serious 1 instance 1 exposed
Issued
Sep 3, 2014
Abate by
Sep 9, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:   a. Welding area east wall, employees were exposed to an electrical hazard, in that, the area in front of the breaker panel for the fuel pumps was used for storage, on or about 08/26/2014.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.305 G01 IV A

Other-than-serious 10 instances 1 exposed
Issued
Sep 3, 2014
Abate by
Sep 9, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a. Welding area, employees were exposed to an electrical hazard, in that, temporary wiring such as extension cords and multi outlet extension strips were permanently installed and used to provide power at the various work areas in the shop, on or about 08/26/2014.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Waste PRO of Florida, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339924987.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.