Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: NATIONAL PARK SERVICE GRAND CANYON, VISITOR AND RESOURCE PROTECTION STATION 1

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NATIONAL PARK SERVICE GRAND CANYON, VISITOR AND RESOURCE PROTECTION STATION 1 in 3 CLINIC ROAD, GRAND CANYON, AZ 86023 (NAICS 712190). OSHA activity number 339926651.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch National Park Service Grand Canyon, Visitor and Resource Protection Station 1 for free Get an email when a new federal OSHA severe-injury report for National Park Service Grand Canyon, Visitor and Resource Protection Station 1 is published. One employer, no account, unsubscribe in one click.
Site address
3 CLINIC ROAD
City
GRAND CANYON
State
AZ
ZIP
86023
Mailing
P.O. BOX 129, GRAND CANYON, AZ 86023
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712190
Employees
75
Ownership type
Federal government (D)

7 citations on file for this inspection.

1910.37 A03

Serious Gravity 1 1 instance 5 exposed
Issued
Jan 5, 2015
Abate by
Jan 9, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit routes were not free and/or unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp were not provided where the exit route was not substantially level.  (a) At the NPS Visitor and Resource Protection Station 1, Workshop/Laundry Room area, exit door was obstructed by tires.
Recent events (1)
  • · Z (S) $0

1910.37 B02

Serious Gravity 1 2 instances 5 exposed
Issued
Jan 5, 2015
Abate by
Jan 29, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit."  (a) At the NPS Visitor and Resource Protection Station 1 Main Conference Room, exits were not clearly marked by a sign "EXIT".
Recent events (1)
  • · Z (S) $0

1910.37 B05

Serious Gravity 1 2 instances 5 exposed
Issued
Jan 5, 2015
Abate by
Jan 9, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet).  (a) At the NPS Visitor and Resource Protection Station 1 Main Conference Room, door leading to the electrical closet was not clearly marked "NOT AN EXIT".
Recent events (1)
  • · Z (S) $0

1910.242 B

Serious Gravity 1 1 instance 5 exposed
Issued
Jan 5, 2015
Abate by
Jan 29, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i..  (a) At the NPS Visitor and Resource Protection Station 1, vehicle bay, air hose used for cleaning was not reduces to 30 psi.
Recent events (1)
  • · Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 5, 2015
Abate by
Jan 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.  (a) At the NPS Visitor and Resource Protection Station 1, Search and Rescue Cache spaces, a re-locatable power tap was used to plug in high amperage electrical appliances such as rope cutter and fan motor.
Recent events (1)
  • · Z (S) $0

1910.303 G01 II

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 5, 2015
Abate by
Jan 29, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage.  (a) At the NPS Visitor and Resource Protection Station 1, Compressor Room, a red container was stored in front of the electrical power panel.
Recent events (1)
  • · Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 5, 2015
Abate by
Jan 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.  (a) At the NPS Visitor and Resource Protection Station 1, Search and Rescue Cache, flexible cord was used to power fan motor for more than three months.
Recent events (1)
  • · Z (S) $0

View National Park Service Grand Canyon, Visitor and Resource Protection Station 1's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339926651.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.