PHILADELPHIA, PA —
OSHA Inspection: R&M MASONRY CONTRACTORS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of R&M MASONRY CONTRACTORS INC. in 410 S FRONT STREET, PHILADELPHIA, PA 19147 (NAICS 238140). OSHA activity number 339928335.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R&M MASONRY CONTRACTORS INC.
- Site address
- 410 S FRONT STREET
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19147
- Mailing
- 412 WELSH RD., PHILADELPHIA, PA 19115
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Feb 19, 2015
- Abate by
- Feb 25, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports. a) Jobsite: Scaffold - The employer did not ensure that all working levels of the fabricated frame scaffold were fully planked or decked between the front uprights and the guardrail supports. Employees were conducting masonry operations approximately 52 feet above ground level. On or about 8/29/14.
Recent events (1)
- — Z (S) $2800
1926.451 F07
- Issued
- Feb 19, 2015
- Abate by
- Feb 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees selected by, and under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. a) Jobsite: Scaffold. No competent person supervised or directed the erection of the supported tubular welded frame scaffold in a manner that ensured the safety of the workers working from the scaffold. Employees were conducting masonry operations from the 8th and 9th working levels, approximately 53 to 62 feet above ground level. On or about 8/29/15.
Recent events (1)
- — Z (S) $0
1926.451 E01
- Issued
- Feb 19, 2015
- Abate by
- Feb 25, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(e)(1): A means of access for scaffold platforms more than 2 feet (0.6 m) above or below a point of access, such as portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used. a) Jobsite: 8th and 9th working platforms, and outrigger - The employer did not provide a safe means of access from one level to another by use of portable ladders, hook-on ladders or other acceptable means. Employees were climbing the scaffold supports to access the 8th and 9th working levels. On or about 8/29/14.
Recent events (1)
- — Z (S) $2800
1926.451 G01 VII
- Issued
- Feb 19, 2015
- Abate by
- Feb 25, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee was not protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Jobsite: 8th and 9th working platform, and outrigger - Employees were not provided with a fall protection system while working from a supported tubular welded frame scaffold. Employees conducting masonry operations were exposed to a 60 foot fall. On or about 8/29/15.
Recent events (1)
- — Z (S) $2800
1926.451 G01 V
- Issued
- Feb 19, 2015
- Abate by
- Feb 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1)(v): Each employee on a walkway located within a scaffold was not protected by a guardrail system (with a minimum 200 pound toprail capacity) installed within 9.5 inches (24.1 cm) of and along at least one side of the walkway. a) Jobsite: 8th and 9th working platforms and outrigger- Walkways used by employees were not equipped with guardrail systems to protect employees from fall hazards. On or about 8/29/15.
Recent events (1)
- — Z (S) $0
More inspections at R&M Masonry Contractors INC.
View R&M Masonry Contractors INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339928335.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.