DALLAS, TX ·
OSHA Inspection: BRIAN GREAM DESIGN BUILD RENOVATE LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BRIAN GREAM DESIGN BUILD RENOVATE LLC in GREENVILLE AVE. AND VICKERY BLVD., DALLAS, TX 75206 (NAICS 238130). OSHA activity number 339930364.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BRIAN GREAM DESIGN BUILD RENOVATE LLC
- Site address
- GREENVILLE AVE. AND VICKERY BLVD.
- City
- DALLAS
- State
- TX
- ZIP
- 75206
- Mailing
- 5414 RICHARD AVE., DALLAS, TX 75206
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1926.100 A
- Issued
- Sep 8, 2014
- Abate by
- Sep 12, 2014
- Penalty
- Initial $1,600 · Current $500 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: This violation occurred on or about August 21, 2014, and at times prior thereto, when employees were exposed to head injury from impact, or falling or flying objects due to not wearing protective helmets while employees installed trusses on an upper level approximately 12 feet above.
Recent events (2)
- · I (S) $500
- · Z (S) $1600
1926.403 B02
- Issued
- Sep 8, 2014
- Abate by
- Sep 18, 2014
- Penalty
- Initial $1,600 · Current $500 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: This violation occurred on or about August 21, 2014, and at times prior thereto, when employees were using electrical receptacles boxes that were not installed inside of the walls to operate an Emglo air compressor and other electric tools.
Recent events (2)
- · I (S) $500
- · Z (S) $1600
1926.501 B13
- Issued
- Sep 8, 2014
- Abate by
- Sep 12, 2014
- Penalty
- Initial $2,800 · Current $1,300 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): This violation occurred on or about August 21, 2014, and at times prior thereto, when employees were exposed to falls from a height approximately 12 feet above a lower level.
Recent events (2)
- · I (S) $1300
- · Z (S) $2800
1926.1051 A
- Issued
- Sep 8, 2014
- Abate by
- Sep 12, 2014
- Penalty
- Initial $2,800 · Current $1,300 Reduced
General-duty citation text
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: This violation occurred on or about August 21, 2014, and at times prior thereto, when employees were exposed to fall hazards while using a folding stepladder to access the second story of a new two story single family residential home. The point of access contained a break in elevation of 19 inches or more between the top of the ladder and the upper level.
Recent events (2)
- · I (S) $1300
- · Z (S) $2800
1926.1053 B04
- Issued
- Sep 8, 2014
- Abate by
- Sep 12, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: This violation occurred on or about August 21, 2014, and at times prior thereto, when employees were exposed to fall hazards while using an 8 foot stepladder with the spreader arms in the closed position to access an upper landing.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.1053 B13
- Issued
- Sep 8, 2014
- Abate by
- Sep 12, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: This violation occurred on or about August 21, 2014, and at times prior thereto, when employees were exposed to fall hazards while with using the top step of an 8 foot stepladder to access an upper landing of a new two story single family residential home.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 238130)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339930364.