Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WEST TEXAS DRUM

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of WEST TEXAS DRUM in 8950 FM 1405 RD, BAYTOWN, TX 77520 (NAICS 425120). OSHA activity number 339931552.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch West Texas Drum — free Get an email when a new federal OSHA severe-injury report for West Texas Drum is published. One employer, no account, unsubscribe in one click.
Establishment
WEST TEXAS DRUM
Site address
8950 FM 1405 RD
City
BAYTOWN
State
TX
ZIP
77520
Mailing
8950 FM 1405 RD, BAYTOWN, TX 77520
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
425120
Employees
70
Ownership type
A

17 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 3, 2014
Abate by
Dec 6, 2014
Penalty
Initial $4,860 · Current $2,430 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition:    a) In the reconditioning unit on the steel 55-gallon side, where steel grit blast media over spray was discharged onto the walkway.
Recent events (2)
  • — I (S) $2430
  • — Z (S) $4860

1910.94 A07

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 3, 2014
Abate by
Dec 6, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.94(a)(7):  Aisles and walkways were not kept clear of steel shot or similar abrasive which created a slipping hazard:  a) In the reconditioning unit on the steel 55-gallon side, where steel grit blast media over spray was discharged onto the walkway.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.22 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 3, 2014
Abate by
Dec 6, 2014
Penalty
Initial $4,860 · Current $2,430 Reduced
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard:    a) In the reconditioning unit on the plastic 55-gallon side, where the water valve was protruding in the walkway near the inspection area.
Recent events (2)
  • — I (S) $2430
  • — Z (S) $4860

1910.23 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 3, 2014
Abate by
Dec 6, 2014
Penalty
Initial $3,240 · Current $1,620 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:    a) In the reconditioning unit on the steel 55-gallon side, where the guardrailing was missing.  The platform was approximately 4 feet above the lower level.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $3240

1910.24 F

Serious Gravity 5 2 instances 4 exposed
Issued
Nov 3, 2014
Abate by
Dec 6, 2014
Penalty
Initial $4,860 · Current $2,430 Reduced
29 CFR 1910.24(f): Rise height and tread width were not uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs:    a) In the reconditioning unit, where the stairs leading to the plastic 55-gallon reconditioning side were not uniform.    b) In the reconditioning unit, where the stairs leading to the blasting area from the steel 55-gallon reconditioning side were not uniform.
Recent events (2)
  • — I (S) $2430
  • — Z (S) $4860

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 3, 2014
Abate by
Dec 6, 2014
Penalty
Initial $2,430 · Current $1,215 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:      a) In the reconditioning unit, where employees had not received a medical evaluation prior to wearing 3M full face and half-face respirators.
Recent events (2)
  • — I (S) $1215
  • — Z (S) $2430

1910.141 A03 I

Serious Gravity 5 1 instance 5 exposed
Issued
Nov 3, 2014
Abate by
Dec 6, 2014
Penalty
Initial $4,050 · Current $2,025 Reduced
29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed:    a) In the reconditioning unit, where the restroom was not maintained in a sanitary condition.
Recent events (2)
  • — I (S) $2025
  • — Z (S) $4050

1910.219 F03

Serious Gravity 5 1 instance 5 exposed
Issued
Nov 3, 2014
Abate by
Dec 6, 2014
Penalty
Initial $3,240 · Current $1,620 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven 7 feet or less above floors or platforms were not enclosed:    a) At the facility, where the chain and sprocket drum/tote conveyor system is embedded within the working platform was not guarded.  Employees have to walk/step over the conveyor system to access their work areas.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $3240

1910.253 B04 III

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 3, 2014
Abate by
Dec 6, 2014
Penalty
Initial $4,860 · Current $2,430 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:     a) Near the old maintenance office, where the oxygen and acetylene cylinders were stored adjacent to one another.
Recent events (2)
  • — I (S) $2430
  • — Z (S) $4860

1910.305 G02 III

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 3, 2014
Abate by
Dec 6, 2014
Penalty
Initial $3,240 · Current $1,620 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    a) In the reconditioning unit near the plastic inspection area, where the strain relief on the flexible cord entering the electrical panel was disconnected.  The electrical panel powered the blower in the inspection area on the steel side.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $3240

1910.1200 F05

Serious Gravity 1 1 instance 5 exposed
Issued
Nov 3, 2014
Abate by
Dec 6, 2014
Penalty
Initial $2,430 · Current $1,215 Reduced
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein:    a) In the reconditioning unit on the steel 55-gallon side, where the plastic 55-gallon drum was not labeled to identify the hydrochloric acid that was contained within.
Recent events (2)
  • — I (S) $1215
  • — Z (S) $2430

1910.1200 G08

Serious Gravity 1 1 instance 5 exposed
Issued
Nov 3, 2014
Penalty
Initial $2,430 · Current $1,215 Reduced
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required safety data sheets (SDSs) for each hazardous chemical and ensure that the SDSs were readily accessible during each work shift in the workplace:    a) At the facility, where the safety data sheets were not maintained for XLW-30G and Steel Grit.
Recent events (2)
  • — I (S) $1215
  • — Z (S) $2430

1910.1200 H01

Serious Gravity 1 1 instance 4 exposed
Issued
Nov 3, 2014
Abate by
Dec 6, 2014
Penalty
Initial $2,430 · Current $1,215 Reduced
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    a) At the facility, where the employees were not effectively trained on the chemicals in their work area.
Recent events (2)
  • — I (S) $1215
  • — Z (S) $2430

1910.134 D01 III

Other-than-serious 1 instance 3 exposed
Issued
Nov 3, 2014
Abate by
Dec 6, 2014
Penalty
Initial $810 · Current $405 Reduced
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:   a) In the reconditioning unit, where the employer had not identified the respiratory hazards for ammonia, carbon monoxide, respirable dusts, and for prior to assigning the use of full face and half-face respirators.
Recent events (2)
  • — I (O) $405
  • — Z (O) $810

1910.134 F02

Other-than-serious 1 instance 1 exposed
Issued
Nov 3, 2014
Abate by
Dec 6, 2014
Penalty
Initial $810 · Current $405 Reduced
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:   a) In the reconditioning unit, where employees were not fit tested prior to wearing 3M full face and half-face respirators.
Recent events (2)
  • — I (O) $405
  • — Z (O) $810

1910.134 H02 I

Other-than-serious 1 instance 1 exposed
Issued
Nov 3, 2014
Abate by
Nov 11, 2014
Penalty
Initial $810 · Current $405 Reduced
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:   a) In the reconditioning unit near the steel inspection area, where a 3M half-face respirator was stored on top of a portable fan under a hand towel.
Recent events (2)
  • — I (O) $405
  • — Z (O) $810

1910.141 C01 I

Other-than-serious 1 instance 5 exposed
Issued
Nov 3, 2014
Abate by
Dec 6, 2014
Penalty
Initial $810 · Current $405 Reduced
29 CFR 1910.141(c)(1)(i): Toilet facilities were not provided in accordance with TABLE J-1 of this Section:  a) In the reconditioning unit, where separate toilet rooms were not provided for each sex.
Recent events (2)
  • — I (O) $405
  • — Z (O) $810

View West Texas Drum's full OSHA safety record →