EDISON, NJ —
OSHA Inspection: RELIANCE PRIVATE LABEL SUPPLEMENTS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of RELIANCE PRIVATE LABEL SUPPLEMENTS in 3775 PARK AVE, EDISON, NJ 08817 (NAICS 325412). OSHA activity number 339933236.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RELIANCE PRIVATE LABEL SUPPLEMENTS
- Site address
- 3775 PARK AVE
- City
- EDISON
- State
- NJ
- ZIP
- 08817
- Mailing
- 3775 PARK AVE, EDISON, NJ 08817
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325412
- Employees
- 200
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.26 C02 VII
- Issued
- Mar 3, 2015
- Penalty
- Initial $2,970 · Current $1,930 Reduced
General-duty citation text
29 CFR 1910.26(c)(2)(vii): Ladders having defects were not taken out of service or set for repair by the maintenance department or the manufacturer. Reliance Private Label Supplements, Edison / Maintenance room- A defective ladder with a broken foot pad was used by employees in the maintenance department exposing them to fall hazards. Observed on or about 12/17/2014
Recent events (3)
- — R (O) $1930
- — C (S) $2970
- — Z (S) $2970
1910.147 C06 I
- Issued
- Mar 3, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $5,940 · Current $3,861 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a) Reliance Vitamin Edison, NJ: The employer did not conduct an annual or more frequent inspection of the energy control procedures to ensure that they were properly implemented during the lockout of equipment such as but not limited to: Stokes Tablet press located in room 5. Observed on or about on 09/04/2014
Recent events (3)
- — R (S) $3861
- — C (S) $5940
- — Z (S) $5940
1910.147 C04 I
- Issued
- Mar 3, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $5,940 · Current $3,861 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): No procedures was developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. a) Reliance Vitamin., Edison, NJ- Lockout procedures were not developed where employee(s) are required to perform maintenance and in service adjustments exposing employees to amputation hazards on machines such as but not limited to the Stokes Tablet Press in Room # 5. b) The Index K120i machine needed to be energized while employees where cleaning the machine in order to jog the machine at a certain speed to clean the compartments. The employer did not developed or document a program for the control of potentially hazardous energy exposing employees to amputation hazards. Observed on or about on 9/04/2014
Recent events (3)
- — R (S) $3861
- — C (S) $5940
- — Z (S) $5940
1910.147 C05 I
- Issued
- Mar 3, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware was not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources. a) Reliance Private Label Supplements, Edison NJ- Machine operators are not provided with locks, keys or other sources of hardware from the employer to isolate, secure or block the machine from the energy sources on the mixer in Room #10 or the stokes tablet press in Room # 5 during operational servicing. Observed on or about on 9/4/2014 and 12/17/2014
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
1910.176 B
- Issued
- Mar 3, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $5,940 · Current $3,861 Reduced
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: a/ Reliance Private Label Supplements/ Edison, NJ - Warehouse Area near production are/ 3rd Rack of unsecured drums of product stored on a rack were not stacked or blocked to prevent falling, exposing the employees to struck by hazards. Observed on or about on 09/4/2014
Recent events (3)
- — R (S) $3861
- — C (S) $5940
- — Z (S) $5940
1910.212 A01
- Issued
- Mar 3, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $6,930 · Current $4,505 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): No methods of machine guarding was provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. a) Press Room, Room # 5 the Stokes tablet press machine all points of operation were not guarded. No guards were provided to protect the employees from ingoing nip points and rotating parts exposing the employees from amputation hazards. 2) The Index K120i was not guarded from the right side of the machine where employees are instructed to fill the hopper. The guard was not provided to protect the employees from ingoing nip point exposing the employees from amputation hazards and caught on hazards. Observed on or about 9/4/2014
Recent events (3)
- — R (S) $4505
- — C (S) $6930
- — Z (S) $6930
1910.303 G01
- Issued
- Mar 3, 2015
- Penalty
- Initial $3,960 · Current $2,574 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment. a) Reliance Private Label Supplements dba Reliance Vitamin Co. Inc., Edison NJ/ Electrical Above Mezzanine Stairs warehouse- Electrical panel boxes rated 600 volts or less were blocked by storage materials from construction being done at the facility and a minimum of 30 inches of space was not maintained only 21.5 inches was maintained. b)Reliance Private Label Supplements dba Reliance Vitamin Co. Inc., Edison NJ/North east region near the production area- The Electrical Panel boxes rated 600 volts or less were blocked by wooden palletes Observed on or 09/04/2014
Recent events (3)
- — R (S) $2574
- — C (S) $3960
- — Z (S) $3960
1910.304 G05
- Issued
- Mar 3, 2015
- Penalty
- Initial $5,940 · Current $3,861 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective. a) Reliance Private Label Supplements, Edison NJ / Room #5 Production Area- The Stokes Tablet Machine power cord was missing the ground blade creating a non-continuous path to ground exposing employees to electrical shock hazards. Observed on or about 09/04/2014
Recent events (3)
- — R (S) $3861
- — C (S) $5940
- — Z (S) $5940
1910.334 A02 II
- Issued
- Mar 3, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): When there was a defect or evidence of damage that could expose an employee to injury, the defective or damaged item was not removed from service until the repairs and tests necessary to render the electric equipment safe had been made: a) Reliance Private Label Supplements, Edison NJ / Room # 5 - A defective extension cord was used by employees and was not removed from service until repairs were made exposing the employees to electric shock hazards. Observed on or about on 09/04/2014
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
1910.157 C01
- Issued
- Mar 3, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $990 · Current $644 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): The employer did not identify the location of fire extinguishers and make them readily accessible to employees without subjecting the employees to possible injury. a) Reliance Private Label Supplements, Edison NJ/ Maintenance Room- Portable fire extinguisher locations are not identified and are not readily accessible to employees, subjecting the employees to injury such as burns. 1) Portable fire extinguishe are blocked by storage materials. Exposing employees to burns. Observed on or about on 12/17/2014
Recent events (3)
- — R (O) $644
- — C (O) $990
- — Z (O) $990
More inspections at Reliance Private Label Supplements
View Reliance Private Label Supplements's full OSHA safety record →
More inspections in this industry (NAICS 325412)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339933236.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.