CUMMING, GA ·
OSHA Inspection: M.N.S. FRAMING CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of M.N.S. FRAMING CONSTRUCTION in 6350 SHILOH WOODS DR. LOT #82, CUMMING, GA 30040 (NAICS 238130). OSHA activity number 339934002.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M.N.S. FRAMING CONSTRUCTION
- Site address
- 6350 SHILOH WOODS DR. LOT #82
- City
- CUMMING
- State
- GA
- ZIP
- 30040
- Mailing
- 4055 SPRING COVE DR., DULUTH, GA 30097
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.501 B13
- Issued
- Sep 22, 2014
- Abate by
- Oct 2, 2014
- Penalty
- Initial $2,400 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Site - On or about 08/28/14 and at times prior thereto employees were building and erecting the external walls on top of the second floor. The floor border was not protected by guardrails, and fall protection equipment was not in use. Employees were exposed to 10 ft. 8.0 in. falls to ground level. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition documentation demonstrating that abatement is complete must be included with your certification
Recent events (2)
- · I (S) $1200
- · Z (S) $2400
1926.501 B14
- Issued
- Sep 22, 2014
- Abate by
- Oct 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, was not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system. a) Site - On or about 08/28/14 and at times prior thereto employees were performing carpentry work on top of the second floor. The window opening on the right side of the building was not protected by guardrails, exposing workers to 10 ft. 8.0 in. falls to ground level. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition documentation demonstrating that abatement is complete must be included with your certification
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.1053 B01
- Issued
- Sep 22, 2014
- Abate by
- Oct 2, 2014
- Penalty
- Initial $1,600 · Current $804 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Site - On or about 08/28/14 and at times prior thereto employees were building and erecting the external walls on top of the second floor. The portable Werner aluminum ladder reached 9.0 ft. above ground level, and did not extend 3.0 feet above the landing surface (situated at 10.0 ft. 8.0 in. above ground level). In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition documentation demonstrating that abatement is complete must be included with your certification
Recent events (2)
- · I (S) $804
- · Z (S) $1600
1926.1060 A01
- Issued
- Sep 22, 2014
- Abate by
- Oct 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1060(a)(1): 1926.1060(a)(1): The employer did not ensure that each employee was trained by a competent person which would enable each employee to recognize hazards related to ladders and stairs, and the procedures to follow to minimize those hazards. a) Site - On or about 08/28/14 and at times prior thereto employees were building and erecting the external walls on top of the second floor. The portable Werner aluminum ladder reached 9.0 ft. above ground level, and did not extend 3.0 feet above the landing surface (situated at 10.0 ft. 8.0 in. above ground level). The employer did not ensure that workers were trained by a competent person in the safe use of ladders, and in the recognition of hazards associated with ladders. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition documentation demonstrating that abatement is complete must be included with your certification
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 238130)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339934002.