OSHA Inspection: APP CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of APP CONSTRUCTION in SIDEWALK PROJECT AT THE WHITECLOUD RESIDENCE BARONA INDIAN RESERVATION, LAKESIDE, CA 92040 (NAICS 238110). OSHA activity number 339935769.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch APP Construction — free Get an email when a new federal OSHA severe-injury report for APP Construction is published. One employer, no account, unsubscribe in one click.
Establishment
APP CONSTRUCTION
Site address
SIDEWALK PROJECT AT THE WHITECLOUD RESIDENCE BARONA INDIAN RESERVATION
City
LAKESIDE
State
CA
ZIP
92040
Mailing
4975 DAFTER DRIVE, SAN DIEGO, CA 92102
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.95 A

Serious Gravity 1 2 instances 2 exposed
Issued
Nov 5, 2014
Abate by
Nov 14, 2014
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used, and maintained in a sanitary and reliable condition wherever it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact:    Located at a family house under new construction on the Barona Reservation, the employer failed to provide the following:      (a) Protective gloves were while using a trowel to smooth out portland cement, exposing employees to the hazard of contacting the cement as described in the material safety sheet.  (b) Eye protection while using a trowel to smooth portland cement and while handling the chute of a concrete truck that poured portland cement into the formwork for the sidewalk as described in the material safety sheet exposing employees to the hazard of portland cement contact.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.303 C03

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 5, 2014
Abate by
Nov 14, 2014
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1926.303(c)(3): All other portable abrasive wheels used for external grinding, were not provided with safety guards (protection hoods) meeting the requirements of paragraph (c)(5) of this section:    Located at a family house under new construction on the Barona Reservation, the employer failed to provide guarding protection for a 4.5-inch Drill Master right angle grinder with a 4 inch diameter composite wheel, exposing employees to struck-by and laceration hazards from flying materials.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.404 B01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 5, 2014
Abate by
Nov 14, 2014
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.    Located at a family house under new construction on the Barona Reservation, the employer failed to provide ground fault circuit interrupters for electrical equipment exposing the employee to the hazards of electrical shock.