WARREN, OH —
OSHA Inspection: CONCORD STEEL INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CONCORD STEEL INC in 1451 BUENA VISTA AVE, WARREN, OH 44483 (NAICS 332999). OSHA activity number 339937906.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONCORD STEEL INC
- Site address
- 1451 BUENA VISTA AVE
- City
- WARREN
- State
- OH
- ZIP
- 44483
- Mailing
- PO BOX 191, WARREN, OH 44482
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 29
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.107 C05
- Issued
- Oct 20, 2014
- Abate by
- Oct 28, 2014
- Penalty
- Initial $3,060 · Current $2,142 Reduced
General-duty citation text
29 CFR 1910.107(c)(5): Electrical equipment in a spraying area, where on deposits of combustible residues may readily accumulate, was located in a spraying area and was not specifically approved for locations containing deposits of readily ignitable residue: A pendant control box on a hoist in the painting department was coated with paint.
Recent events (2)
- — I (S) $2142
- — Z (S) $3060
1910.107 G02
- Issued
- Oct 20, 2014
- Abate by
- Oct 28, 2014
- Penalty
- Initial $2,295 · Current $1,607 Reduced
General-duty citation text
29 CFR 1910.107(g)(2): Spraying area(s) were not kept free from the accumulation of deposits of combustible residues: There was an accumulation of dried paint residue on the rear wall of the paint booth.
Recent events (2)
- — I (S) $1606.5
- — Z (S) $2295
1910.157 G02
- Issued
- Oct 20, 2014
- Abate by
- Nov 14, 2014
- Penalty
- Initial $2,295 · Current $1,607 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting was not provided to all employees upon initial employment, and at least annually thereafter: Although portable fire extinguishers were available for employee use, neither initial, nor annual retraining was provided. Note: Employer may exercise one of the following options. 1. Provide portable fire extinguishers as specified in 29 CFR1910.157(c)(1), meet the distribution requirements per 29 CFR1910.157(d) (75 feet to the nearest extinguisher for Class A fires and 50 feet to the nearest unit for Class B fires), and provide training and education for all employees in the use of such equipment and the hazards associated with incipient stage firefighting as required in 29 CFR 1910.157(g). The other sections of 29 CFR also apply. 2. Provide extinguishers as specified in 29 CFR 1910.157(c)(1),designate certain employees to be the only employees authorized to use such equipment and require all other employees to immediately evacuate upon the sounding of the fire alarm, establish this in writing in an emergency action plan as outlined in 29 CFR1910.38(a) and train/educate designated employees per 1910.157(g).Utilizing this option exempts the employer from distribution requirements of 29 CFR 1910.157(d). 3. Establish a written fire safety policy which requires the immediate and total evacuation of employees from the workplace upon the sounding of a fire alarm signal. This policy shall include an emergency action plan and a fire prevention plan as specified in 29CFR 1910.38(a) and (b). Utilizing this option exempts the employer from the requirements of 29 CFR 1910.157 to include the need for providing portable fire equipment unless a specific standard requires that a portable fire extinguisher be provided (such as those requirements in 29 CFR 1910.106/107 related to use/storage of flammable/combustible liquids). If extinguishers are provided, but not intended for employee use, 29 CFR 1910.157(e) and (f) are still applicable (inspection, maintenance, and testing of equipment).
Recent events (2)
- — I (S) $1606.5
- — Z (S) $2295
More inspections at Concord Steel INC