GRAND JUNCTION, CO —
OSHA Inspection: CAPCO, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CAPCO, INC. in 1328 WINTERS AVE., GRAND JUNCTION, CO 81501 (NAICS 332992). OSHA activity number 339941080.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CAPCO, INC.
- Site address
- 1328 WINTERS AVE.
- City
- GRAND JUNCTION
- State
- CO
- ZIP
- 81501
- Mailing
- P.O. BOX 1028, GRAND JUNCTION, CO 81501
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332992
- Employees
- 260
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.119 O01
- Issued
- Dec 30, 2014
- Abate by
- Jan 27, 2015
- Penalty
- Initial $3,400 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(o)(1): The employer did not certify that they have evaluated compliance with the provisions of this section at least every three years to verify that the procedures and practices developed under the standard were adequate and were being followed: (a)CAPCO, Inc. at 1328 Winters Ave., Grand Junction, CO 81501: On and before September 3rd, 2014, the employer did not certify that they had evaluated compliance with this section in that the employer did not provide documentation to show that a compliance audit had ever been performed. The condition exposed employees to explosion hazards. Abatement note: 29 CFR 1910.109(k)(2) provides that the manufacturer of explosives as defined in 29 CFR 1910.109(a)(3) of this section shall also meet the requirements contained in 29 CFR 1910.119.
Recent events (2)
- — I (S) $0
- — Z (S) $3400
1910.147 C06 I
- Issued
- Dec 30, 2014
- Abate by
- Jan 27, 2015
- Penalty
- Initial $4,250 · Current $2,550 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct periodic inspections of the energy control procedures at least annually to ensure that the procedure and the requirement of this standard were being followed: (a)CAPCO, Inc. at 1328 Winters Ave., Grand Junction, CO 81501: On and before September 3rd, 2014, the employer did not conduct annual inspections of the energy control procedures at least annually to ensure that lockout tagout procedures were being followed. The condition exposed employees to amputation and burn hazards. Abatement note: 29 CFR 1910.147(c)(6)(ii) also provides that the employer shall certify that the periodic inspections have been performed.
Recent events (2)
- — I (S) $2550
- — Z (S) $4250
1910.335 A01 I
- Issued
- Dec 30, 2014
- Abate by
- Jan 27, 2015
- Penalty
- Initial $4,250 · Current $2,550 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed: (a)CAPCO, Inc. at 1328 Winters Ave., Grand Junction, CO 81501: On and before September 3rd, 2014, the employer did not ensure that maintenance employees wore appropriate electrical protective equipment when performing work on energized panels up to 208 volts, and when performing voltage testing on energized circuits up to 480 volts. The employees performed this work without wearing: 1) rubber insulated gloves; 2) arc-rated long-sleeve shirts and pants (or coveralls) having an a minimum arc-rating of 8; 3) arc-rated flash suit hoods, or arc-rated face shields and balaclava with a minimum arc-rating of 8. Conditions exposed employees to electrical shock, arc flash, and arc blast hazards. Abatement note: NFPA 70E, 2012 Edition, Table 130.7(C)(15)(a) and Table 130.7(C)(16) categorize activities into risk groups, and describe the protective clothing and personal protective equipment associated for each group. This criteria provides that if voltage testing were being performed on energized 480 volt circuits, the PPE should satisfy an arc-rating of 8 based on Hazard/Risk Category 2. Table 130.7(C)(15)(a) also provides that rubber insulating gloves be worn for voltage testing both 208 and 480 volt circuits. Note that the purchase of equipment that is too heavy, such as arc-flash suits with an arc-rating of 32, may cause the employees not to wear it because it may become too hot, when gear with only an arc-rating of 8 is required.
Recent events (2)
- — I (S) $2550
- — Z (S) $4250
1910.132 D02
- Issued
- Dec 30, 2014
- Abate by
- Jan 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the dates of the hazard assessment, and which identifies the document as a certification of hazard assessment: (a)CAPCO, Inc. at 1328 Winters Ave., Grand Junction, CO 81501: On and before September 3rd, 2014, the employer did not identify a document as a written hazard assessment and did not certify that a written hazard assessment was performed. The condition exposed employees to physical injuries associated with the lack of PPE, including electrical shock and burn hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Capco, INC.
View Capco, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332992)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339941080.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.