COEYMANS, NY —
OSHA Inspection: WILLIAM J. O'ROURKE, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WILLIAM J. O'ROURKE, INC. in RIVERVIEW ROAD, COEYMANS, NY 12045 (NAICS 238190). OSHA activity number 339942740.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WILLIAM J. O'ROURKE, INC.
- Site address
- RIVERVIEW ROAD
- City
- COEYMANS
- State
- NY
- ZIP
- 12045
- Mailing
- 2007 NEW SCOTLAND ROAD., SLINGERLANDS, NY 12159
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238190
- Employees
- 12
- Ownership type
- A
Citations
9 citations on file for this inspection.
1926.100 A
- Issued
- Oct 22, 2014
- Penalty
- Initial $1,080 · Current $810 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) Jobsite - on or about September 8, 2014 - a struck-by hazard existed on site. Employees were not wearing hard hats while erecting wall forms.
Recent events (2)
- — I (S) $810
- — Z (S) $1080
1926.451 B01 I
- Issued
- Oct 22, 2014
- Penalty
- Initial $1,080 · Current $810 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. (a) Jobsite - on or about September 8, 2014 - three form bracket scaffold planks were only 6 inches wide. The spacing on these brackets were designed to accommodate a 10 inch wide scaffold plank.
Recent events (2)
- — I (S) $810
- — Z (S) $1080
1926.451 E01
- Issued
- Oct 22, 2014
- Penalty
- Initial $1,080 · Current $810 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist or similar surface was not used: (a) Jobsite - on or about September 8, 2014 - a proper means of egress was not provided for the wall form scaffold system. Elevation of the scaffold deck to the ground was approximately 27 inches to 28-1/2 inches.
Recent events (2)
- — I (S) $810
- — Z (S) $1080
1926.451 F03
- Issued
- Oct 22, 2014
- Penalty
- Initial $1,080 · Current $810 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: (a) Jobsite - on or about September 8, 2014 - the wall form scaffold system was not inspected by a competent person to evaluate damaged planking that was used as part of the scaffold deck.
Recent events (2)
- — I (S) $810
- — Z (S) $1080
1926.451 F04
- Issued
- Oct 22, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(4): Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired: (a) Jobsite - on or about September 8, 2014 - damaged planking was used as part of the scaffold deck. Two planks were dry-rotted and cracked.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F07
- Issued
- Oct 22, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person: (a) Jobsite - on or about September 8, 2014 - the wall form scaffold system was not erected by a competent person. Observed defects include damaged planking, inadequate scaffold deck widths and no proper means of egress.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.701 B
- Issued
- Oct 22, 2014
- Penalty
- Initial $1,440 · Current $1,080 Reduced
General-duty citation text
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: (a) Jobsite - on or about September 8, 2014 - an impalement hazard existed on site. Approximately 700 pieces of #5 rebar (5/8" diameter reinforcing steel) protruding from the footings were not capped.
Recent events (2)
- — I (S) $1080
- — Z (S) $1440
1926.50 D01
- Issued
- Oct 22, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.50(d)(1): First-aid supplies were not easily accessible when required: (a) Jobsite - on or about September 8, 2014 - no first aid supplies were on site.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.150 C01 VI
- Issued
- Oct 22, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas were being used on the jobsite: (a) Jobsite - on or about September 8, 2014 - no fire extinguisher was on site for the flammable and combustible liquids such as form oil and gasoline.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at William J. O'Rourke, INC.
View William J. O'Rourke, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238190)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339942740.