Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: DIAMOND WINDOWS & DOORS MFG. INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DIAMOND WINDOWS & DOORS MFG. INC in 99 EAST COTTAGE STREET, DORCHESTER, MA 02121 (NAICS 321911). OSHA activity number 339943052.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Diamond Windows & Doors MFG. INC for free Get an email when a new federal OSHA severe-injury report for Diamond Windows & Doors MFG. INC is published. One employer, no account, unsubscribe in one click.
Site address
99 EAST COTTAGE STREET
City
DORCHESTER
State
MA
ZIP
02121
Mailing
99 EAST COTTAGE STREET, DORCHESTER, MA 02121
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321911
Employees
35
Ownership type
A

9 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 10 exposed
Issued
Sep 16, 2014
Abate by
Feb 2, 2015
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  Worksite:  The employer did not develop lockout tagout procedures for each type of machine.
Recent events (2)
  • · I (S) $1750
  • · Z (S) $3500

1910.212 A01

Serious Gravity 5 3 instances 6 exposed
Issued
Sep 16, 2014
Abate by
Dec 19, 2014
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Adjacent to the Maintenance Area:  1) The unused section of the horizontal metal cutting bandsaw was not guarded.  Bay Bow Window Dept.:  2) The guard for the Rigid Cutoff Saw was damaged.  Glass Cutting- Sash and Frame Cleaning Area:  3)  The GED Integrated Solutions Frame Cleaner was not adequately guarded.
Recent events (2)
  • · I (S) $1750
  • · Z (S) $3500

1910.217 B03 I

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 16, 2014
Abate by
Dec 19, 2014
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.217(b)(3)(i): Mechanical power press(es) using full revolution clutches did not incorporate a single-stroke mechanism:  Green Dept.:  The Alva Allen Power Press did not have a single stroke mechanism.
Recent events (2)
  • · I (S) $1750
  • · Z (S) $3500

1910.217 B04 I

Serious Gravity 5 2 instances 3 exposed
Issued
Sep 16, 2014
Abate by
Dec 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.217(b)(4)(i): Pedal mechanism(s) on mechanical power press(es) full revolution clutches were not protected to prevent unintended operation from falling or moving objects or by accidental stepping onto the pedals:  Green Dept.:  1)   The foot pedal of the Bliss Power Press was not covered.  2)   The foot pedal of the Alva Allen Power was not covered.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.217 B08 III

Serious Gravity 5 2 instances 3 exposed
Issued
Sep 16, 2014
Abate by
Dec 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.217(b)(8)(iii): Mechanical power press control(s) did not incorporate a type of drive motor starter that would disconnect the drive motor from the power source in event of control voltage or power source failure and require operation of the motor start control before the machine can operate.  Green Dept.:  1)   The Bliss Power Press did not have a magnetic motor starter box.  2)   The Alva Allen Power Press did not have a magnetic motor starter box.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.217 C01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 16, 2014
Abate by
Dec 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power presses:  Green Dept.:  The point of operation of the Bliss Power Press was not guarded.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.217 C02 I A

Serious Gravity 5 2 instances 5 exposed
Issued
Sep 16, 2014
Abate by
Dec 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.217(c)(2)(i)(a): Point of operation guards on mechanical power presses did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guards.:  Green Dept.:  1)  The point of operation guard for the Alva Allen Power Press was inadequate.  Assembly Dept.:  2)  The point of operation guard for the Press Rite Power Press did not prevent a worker from reaching over the top of the guard into the die area.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.219 D01

Serious Gravity 5 3 instances 6 exposed
Issued
Sep 16, 2014
Abate by
Dec 19, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.219(d)(1): Pulleys with parts seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  Maintenance Room:  1)  The pulley and belt drive of the Alva Allen Power Press was not enclosed by a guard.  Green Dept.:  2)  The pulley and belt drive of the Alva Allen Power Press was not enclosed by a guard.  Assembly Dept.:  3)  The pulley and belt drive of the Press Rite Power Press was not enclosed by a guard.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1910.305 G01 I

Other-than-serious 1 instance 2 exposed
Issued
Sep 16, 2014
Abate by
Nov 5, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(i): Flexible cords and cables were not approved or conditions of use and location:  Assembly Dept.:  The cord of the Press Rite Power Press was damaged.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Diamond Windows & Doors MFG. INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339943052.