ELKHORN, NE —
OSHA Inspection: RONALDO LOPEZ FAJARDO
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of RONALDO LOPEZ FAJARDO in 20641 CORRAL RD, ELKHORN, NE 68022 (NAICS 238160). OSHA activity number 339943805.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RONALDO LOPEZ FAJARDO
- Site address
- 20641 CORRAL RD
- City
- ELKHORN
- State
- NE
- ZIP
- 68022
- Mailing
- 5320 N 24TH ST, OMAHA, NE 68110
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.501 B13
- Issued
- Nov 19, 2014
- Abate by
- Jan 8, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor was an alternative fall protection plan which meets the requirements of �1926.502(k) developed and implemented: 20641 Corral Rd., Elkhorn, NE 68022 (Job-site): The employer is failing ensure that fall protection was provided for employees who were working on the roof of a home which was approximately 10 and 13 feet from a lower level. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed.
Recent events (1)
- — Z (S) $2800
1926.503 A01
- Issued
- Nov 19, 2014
- Abate by
- Jan 8, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: 20641 Corral Rd., Elkhorn, NE 68022 (Job-site): The employer is failing to ensure that they had a training program to ensure that employees minimized hazards when exposed to fall hazards. The employer did not ensure that employees knew to use adequate fall protection when they were performing residential roofing work on a house which was approximately 10 and 13 feet from a lower level. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed.
Recent events (1)
- — Z (S) $2800
1926.1053 B05 I
- Issued
- Nov 19, 2014
- Abate by
- Jan 8, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and top support): 20641 Corral Rd., Elkhorn, NE 68022 (Job-site): The employer is failing to ensure that the portable ladder being used by employees to access the roof was being used at an angle of approximately one-quarter the working length of the ladder. The ladder was being used at height of the top support of approximately 10 feet high and 6 feet distance between the foot and top support). Abatement certification is required for this violation. Abatement certification sheet is enclosed with the citation.
Recent events (1)
- — Z (S) $1600
1926.1053 B16
- Issued
- Nov 19, 2014
- Abate by
- Jan 8, 2015
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladder(s) with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identified them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: 20641 Corral Rd., Elkhorn, NE 68022 (Job-site): The employer is failing to ensure that a portable ladder with structural defects (a bent stability foot), which was being used by employees to access an roof, was taken out of service. Abatement certification is required for this violation. Abatement certification sheet is enclosed with the citation.
Recent events (1)
- — Z (S) $2400
1926.1060 A
- Issued
- Nov 19, 2014
- Abate by
- Jan 8, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways: 20641 Corral Rd., Elkhorn, NE 68022 (Job-site): The employer is failing to ensure employees were trained to recognize hazards related to ladders and trained in the procedures to be followed to minimize these hazards: Employees were using two portable ladders to access an upper landing surfaces; The employer is failing to ensure that the portable ladder being used by employees to access the roof was being used at an angle of approximately one-quarter the working length of the ladder. The ladder was being used at height of the top support of approximately 10 feet high and 6 feet distance between the foot and top support). The employer is failing to ensure that the portable ladder being used by employees to access the roof with the ladder that had a bent stability foot and was not taken out of service. Abatement certification is required for this violation. Abatement certification sheet is enclosed with the citation.
Recent events (1)
- — Z (S) $1600
More inspections in this industry (NAICS 238160)
More inspections in NE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339943805.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.