CORPUS CHRISTI, TX —
OSHA Inspection: R M MASONRY & STUCCO INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of R M MASONRY & STUCCO INC in 4657 OCEAN DR, CORPUS CHRISTI, TX 78412 (NAICS 238140). OSHA activity number 339944043.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R M MASONRY & STUCCO INC
- Site address
- 4657 OCEAN DR
- City
- CORPUS CHRISTI
- State
- TX
- ZIP
- 78412
- Mailing
- 5700 NORTH BEACH #404, HALTOM CITY, TX 76137
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 10
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 G01
- Issued
- Sep 25, 2014
- Abate by
- Oct 24, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. At this worksite, two employees applied stucco from a scaffold at heights greater than ten feet in height with no fall protection.
Recent events (1)
- — Z (S) $2800
1926.451 G04
- Issued
- Sep 25, 2014
- Abate by
- Oct 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4): Guardrail systems installed to meet the requirements of this section did not comply with the provisions listed in subparagraphs (i) through (xv) of this paragraph. At this worksite, two employees applied stucco on an incomplete scaffold at heights greater than 10 feet where guardrails were not installed.
Recent events (1)
- — Z (S) $0
1926.451 H02 II
- Issued
- Sep 25, 2014
- Abate by
- Oct 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: At this worksite where employees applied stucco from a scaffold at heights greater than 10 feet, did not bare any toeboards.
Recent events (1)
- — Z (S) $0
1926.51 A05
- Issued
- Sep 25, 2014
- Abate by
- Oct 9, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.51(a)(5): Where single service cups (to be used but once) were supplied, both a sanitary container for the unused cups and a receptacle for disposing of the used cups were not provided: At this worksite, employees were not furnished disposable drinking cups.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 238140)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339944043.