Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PYRAMID ELECTRIC, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of PYRAMID ELECTRIC, INC. in 1030 JEFFERSON ST, MEMPHIS, TN 38104 (NAICS 238210). OSHA activity number 339944993.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pyramid Electric, INC. — free Get an email when a new federal OSHA severe-injury report for Pyramid Electric, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1030 JEFFERSON ST
City
MEMPHIS
State
TN
ZIP
38104
Mailing
7555 APPLING CENTER DR, MEMPHIS, TN 38133
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
67
Ownership type
A

3 citations on file for this inspection.

1910.1200 E01

Other-than-serious 1 instance 2 exposed
Issued
Sep 30, 2014
Abate by
Oct 27, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): Employer had not developed, implemented and/or maintained a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): (Construction Reference: 1926.59)   (a) On or about September 9, 2014, at the VA Medical Center located at 1030 Jefferson Ave, Memphis, TN, Pyramid Electrical employees were exposed to various hazardous materials (including but not limited to WD40; Smoke; Spray paint; PVC cement) and did not have a copy of their written hazard communication program on site.  Without proper information on hazardous materials, employees could mis-handle hazardous materials and expose themselves to skin, eye, and respiratory irritations.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $0

1910.1200 E01 I

Other-than-serious 1 instance 2 exposed
Issued
Sep 30, 2014
Abate by
Oct 27, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet.   (a) On or about September 9, 2014, at the VA Medical Center located at 1030 Jefferson Ave, Memphis, TN, Pyramid Electrical employees were exposed to various hazardous materials (including but not limited to WD40; Smoke; Spray paint; PVC cement) and did not have a chemical list of hazardous materials used on site.  Without proper information on hazardous materials, employees could mis-handle hazardous materials and expose themselves to skin, eye, and respiratory irritations.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $0

1910.1200 G01

Other-than-serious 3 instances 2 exposed
Issued
Sep 30, 2014
Abate by
Oct 27, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use.  (a) On or about September 9, 2014, at the VA Medical Center located at 1030 Jefferson Ave, Memphis, TN, Pyramid Electrical employees were exposed to various hazardous materials (including but not limited to WD40; Smoke; Spray paint; PVC cement) and did not have Safety Data Sheets (SDS's) on site.  Without proper information on hazardous materials, employees could mis-handle hazardous materials and expose themselves to skin, eye, and respiratory irritations.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $0

View Pyramid Electric, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339944993.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.