Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: S I T INC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of S I T INC in 11801 MAHONING AVE, NORTH JACKSON, OH 44451 (NAICS 314999). OSHA activity number 339945511.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch S I T INC for free Get an email when a new federal OSHA severe-injury report for S I T INC is published. One employer, no account, unsubscribe in one click.
Establishment
S I T INC
Site address
11801 MAHONING AVE
City
NORTH JACKSON
State
OH
ZIP
44451
Mailing
11801 MAHONING AVE, NORTH JACKSON, OH 44451
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
314999
Employees
9
Ownership type
Private (A)

7 citations on file for this inspection.

1910.132 D02

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 1, 2014
Abate by
Oct 21, 2014
Penalty
Initial $1,200 · Current $500 Reduced
29 CFR 1910.132(d)(2):  The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed:      No certification was prepared for employees who are required to use gloves when handling chemicals and eye protection when they use a pressure washer.
Recent events (2)
  • · I (S) $500
  • · Z (S) $1200

1910.133 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 1, 2014
Abate by
Oct 21, 2014
Penalty
Initial $0 · Current $0
29 CFR  1910.133(a)(1): Protective eye and face equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:    Employees wore  no eye protection when they used a pressure washer to clean printing screens.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.157 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 1, 2014
Abate by
Oct 21, 2014
Penalty
Initial $2,400 · Current $1,200 Reduced
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting:      Although portable fire extinguishers were available for employee use, neither initial, nor annual retraining was provided.      Note:  Employer may exercise one of the following options.      1.  Provide portable fire extinguishers as specified in 29 CFR1910.157(c)(1), meet the distribution requirements per 29 CFR1910.157(d) (75 feet to the nearest extinguisher for Class A fires and 50 feet to the nearest unit for Class B fires), and provide training and education for all employees in the use of such equipment and the hazards associated with incipient stage firefighting as required in 29 CFR 1910.157(g). The other sections of 29 CFR also apply.      2.  Provide extinguishers as specified in 29 CFR 1910.157(c)(1),designate certain employees to be the only employees authorized to use such equipment and require all other employees to immediately evacuate upon the sounding of the fire alarm, establish this in writing in an emergency action plan as outlined in 29 CFR1910.38(a) and train/educate designated employees per 1910.157(g).Utilizing this option exempts the employer from distribution requirements of 29 CFR 1910.157(d).      3.  Establish a written fire safety policy which requires the immediate and total evacuation of employees from the workplace upon the sounding of a fire alarm signal.  This policy shall include an emergency action plan and a fire prevention plan as specified in 29CFR 1910.38(a) and (b).  Utilizing this option exempts the employer from the requirements of 29 CFR 1910.157 to include the need for providing portable fire equipment unless a specific standard requires that a portable fire extinguisher be provided (such as those requirements in 29 CFR 1910.106/107 related to use/storage of flammable/combustible liquids).  If extinguishers are provided, but not intended for employee use, 29 CFR 1910.157(e) and (f) are still applicable (inspection, maintenance, and testing of equipment).
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2400

1910.212 A05

Deleted Serious Gravity 1 1 instance 7 exposed
Issued
Oct 1, 2014
Abate by
Oct 11, 2014
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:    A portable pedestal cooling fan in the office had no guard on the front side of the blade.
Recent events (2)
  • · I (S) $0
  • · Z (S) $1200

1910.1200 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 1, 2014
Abate by
Nov 28, 2014
Penalty
Initial $2,400 · Current $1,200 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met and which also includes the items listed in (e)(1)(i) and (ii):      No written program was developed and implemented for employees who work with inks, adhesive and cleaners that contain hazardous chemicals including, but not limited to naphtha, cyclohexanone, isobutane  and sodium metaperiodate.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2400

1910.1200 H01

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 1, 2014
Abate by
Nov 28, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1) Employees were not provided with effective information and training on hazardous chemicals in their work area:      No training was provided for employees who work with inks, adhesive and cleaners that contain hazardous chemicals including, but not limited to naphtha, cyclohexanone, isobutane  and sodium metaperiodate.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.303 B02

Deleted Other-than-serious 1 instance 2 exposed
Issued
Oct 1, 2014
Abate by
Oct 11, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2):  Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    A power strip lying on the floor was used to power the electric stain remover sprayer.  Power strips are not permitted for industrial use.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339945511.