Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MARK SELMER

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of MARK SELMER in 488 BROADWAY, ALBANY, NY 12206 (NAICS 238220). OSHA activity number 339946733.

Watch Mark Selmer — free Get an email when a new federal OSHA severe-injury report for Mark Selmer is published. One employer, no account, unsubscribe in one click.
Establishment
MARK SELMER
Site address
488 BROADWAY
City
ALBANY
State
NY
ZIP
12206
Mailing
384 MADISON AVENUE, ALBANY, NY 12210
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.20(b)(2):  The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):    (a) Jobsite - on or about September 9, 2014 - regular inspections of the site were not performed by a competent person that was designated by the employer.  Employees were exposed to fall and electrical hazards on this site.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.502 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(b)(1):  The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level:  (a) Second Story Floor - on or about September 9, 2014 - employees were exposed to fall hazard while performing plumbing installations.  The window openings had a sill height of 31 inches.  Elevation to the lower roof deck was approximately 12 feet, 8 inches.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 A02 II E

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $1200.00 · Current $920.00 Reduced
29 CFR 1926.405(a)(2)(ii)(E):  Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage:    (a) Second Story Floor - on or about September 9, 2014 - four bulb cages for the temporary construction lighting were missing, exposing the fluorescent light bulbs to breakage.  These bulbs were suspended between 40 inches to 76 inches from the floor.  Thereby, the light bulbs were not guarded by location.
Recent events (2)
  • — I (S) $920
  • — Z (S) $1200

1926.403 B02

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.403(b)(2):  Listed, labeled or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  (a) Second Story Floor - on or about September 9, 2014 - electric tools were plugged into a relocatable power tap.  This device is not designed or rated to be used on a construction site.  (b) Second Story Floor, Maiden Lane Side - on or about September 9, 2014 - electric tools were plugged into a two-gang 119 volt receptacle that was not mounted in accordance with the listing requirements of this outlet.