Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NORTH SHORE NEON SIGN CO.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NORTH SHORE NEON SIGN CO. in 295 SKIDMORE RD., DEER PARK, NY 11729 (NAICS 238990). OSHA activity number 339947368.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch North Shore Neon Sign CO. — free Get an email when a new federal OSHA severe-injury report for North Shore Neon Sign CO. is published. One employer, no account, unsubscribe in one click.
Site address
295 SKIDMORE RD.
City
DEER PARK
State
NY
ZIP
11729
Mailing
295 SKIDMORE RD., DEER PARK, NY 11729
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
50
Ownership type
A

3 citations on file for this inspection.

1910.178 A06

Other-than-serious 3 instances 18 exposed
Issued
Mar 9, 2015
Abate by
May 1, 2015
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates and markings were in place:    a) Workplace, 295 Skidmore Rd., Deer Park, NY- Employees operate a Hyster 18,000lb capacity diesel powered lift with a nameplate which was illegible and the model and serial number could not be read; on or about 9/10/14.    b) Workplace, 295 Skidmore Rd., Deer Park, NY- Employees were operate a Hyster 5,200lb capacity diesel powered lift with a name plate which was illegible and the model and serial number could not be read; on or about 9/10/14.    c) Workplace, 295 Skidmore Rd., Deer Park, NY- Employees were operate a Komatsu 8,200lb capacity diesel powered lift with a name plate which was illegible and the model and serial number could not be read; on or about 9/10/14.     Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (3)
  • — F (O) $0
  • — C (S) $3500
  • — Z (S) $3500

1910.178 Q07

Other-than-serious 4 instances 18 exposed
Issued
Mar 9, 2015
Abate by
May 1, 2015
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:    a) Workplace, 295 Skidmore Rd., Deer Park, NY- Employees operated a Hyster diesel forklift, model and serial number on nameplate were illegible, without examining the vehicle prior to use; on or about 9/10/14.    b) Workplace, 295 Skidmore Rd., Deer Park, NY- Employees operated a Hyster Diesel forklift, 5,200lb capacity, model and serial number on nameplate were illegible, without examining the vehicle prior to use; on or about 9/10/14.    c) Workplace, 295 Skidmore Rd., Deer Park, NY- Employees operated a Komatsu Diesel forklift, 8,200lb capacity, model and serial number on nameplate were illegible, without examining the vehicle prior to use; on or about 9/10/14.    d) Workplace, 295 Skidmore Rd., Deer Park, NY- Employees operated a Doosan Diesel forklift, 4,900lb capacity, model #305-3, serial #K-02791, without examining the vehicle prior to use; on or about 9/10/14.                 Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. 29 CFR 1910.178(p)(1): If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition.    a) Workplace, 295 Skidmore Rd., Deer Park, NY- A Hyster diesel powered lift (Model and serial number on nameplate was illegible) was being operated with a damaged and disconnected headlight; on or about 9/10/14.     Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (3)
  • — F (O) $0
  • — C (S) $3500
  • — Z (S) $3500

1910.178 L01 I

Serious Gravity 10 4 instances 18 exposed
Issued
Mar 9, 2015
Abate by
May 1, 2015
Penalty
Initial $4,900 · Current $4,900
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    a) Workplace, 295 Skidmore Rd., Deer Park, NY- The employer authorized employees to operate forklifts, such as but not limited to a Hyster diesel powered lift, model and serial number on nameplate was illegible; a Hyster 5,200lb diesel powered lift, model and serial number on nameplate was illegible; a Komatsu 8,200lb capacity diesel powered lift, model and serial number on nameplate was illegible; and a Doosan 4,900  capacity diesel powered lift, Model #305-3, serial number K-02791, without providing powered industrial equipment training that included a combination of formal instruction, practical training and a performance evaluation prior to operating the forklift when the employee was initially assigned to operate the equipment; on or about 9/10/14.    Note:  In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (3)
  • — F (S) $4900
  • — C (S) $4900
  • — Z (S) $4900

View North Shore Neon Sign CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339947368.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.