Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: BENITO CRUZ

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BENITO CRUZ in 801 SOUTH WARNOCK STREET, PHILADELPHIA, PA 19147 (NAICS 238140). OSHA activity number 339947988.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Benito Cruz for free Get an email when a new federal OSHA severe-injury report for Benito Cruz is published. One employer, no account, unsubscribe in one click.
Establishment
BENITO CRUZ
Site address
801 SOUTH WARNOCK STREET
City
PHILADELPHIA
State
PA
ZIP
19147
Mailing
1543 VENUS DRIVE, VINELAND, NJ 08360
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
2
Ownership type
A

11 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 13, 2014
Abate by
Nov 19, 2014
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    a) Jobsite, 801 South Warnock Street - A laborer was working below a fabricated frame scaffold with bricks stored 32 feet above ground level. The exposed employee was not provided with head protection, observed on or about 7/7/14.
Recent events (2)
  • · I (S) $720
  • · Z (S) $1200

1926.451 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 13, 2014
Abate by
Nov 19, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph.    a) Jobsite, 801 South Warnock Street - An employee was performing masonry operations on a fabricated frame scaffold 30 feet above the ground level without utilzing guys, ties or braces to prevent tipping and/or collapse, observed on or about 7/7/14.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1926.451 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 13, 2014
Abate by
Nov 19, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access:        a) Jobsite, 801 South Warnock Street - An employee was scaling down fabricated scaffold frames up to 30 feet above the ground level without the use of a ladder, observed on or about 7/7/14.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1926.451 F06

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 13, 2014
Abate by
Nov 19, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6):    a) Jobsite, 801 South Warnock Street - An employee was performing masonry operations on a fabricated frame scaffold within 4 feet of an unprotected 240 volt power line, observed on or about 7/7/14.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1926.451 F07

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 13, 2014
Abate by
Jan 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person:    a) Jobsite, 801 South Warnock Street - A fabricated frame scaffold was erected within 4 feet of an unprotected 240 volt power line without a competent person on site, on or about 7/7/14.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 G04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 13, 2014
Abate by
Nov 19, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews:    a) Jobsite, 801 South Warnock Street - An employee was performing masonry operations on an outrigger of a fabricated frame scaffold 30 feet above ground level without fall protection on the ends, observed on or about 7/7/14.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1926.454 A

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 13, 2014
Abate by
Jan 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:    a) Jobsite, 801 South Warnock Street - An employee was performing masonry operations on an outrigger of a fabricated frame scaffold 30 feet above ground level without being trained in scaffold safety. The exposed employee did not know the trigger height for fall protection on fabricated frame scaffolds, on or about 7/7/14.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 H02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 13, 2014
Abate by
Nov 19, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below:Note:  This requirement does not apply to float (ship) scaffolds where an edging of 3/4 inch x 1 1/2 inch (2 x 4 cm) wood or equivalent was used in lieu of toeboards:    a) Jobsite, 801 South Warnock Street - As an unprotected laborer was working on the ground level, masonry supplies such as bricks, etc. were being stored on the scaffold 32 feet above ground level without a toeboard, observed on or about 7/7/14.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1910.1200 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 13, 2014
Abate by
Jan 8, 2015
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): (Construction Reference 1926.59)    a) Jobsite, 801 South Warnock Street - Employees were handling Keystone Portland Cement containing tricalcium silicate cas number 12168-85-3 without a written hazard communication program readily available on or about 7/7/14.
Recent events (2)
  • · I (S) $720
  • · Z (S) $1200

1910.1200 G08

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 13, 2014
Abate by
Jan 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):   The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s): (Construction Reference 1916.59)    a) Jobsite, 801 South Warnock Street - Employees were handling Keystone Portland Cement containing tricalcium silicate cas number 12168-85-3 without a safety data sheet readily available, observed on or about 7/7/14.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 H01

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 13, 2014
Abate by
Jan 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59)    a) Jobsite, 801 South Warnock Street - Employees were handling Keystone Portland Cement containing tricalcium silicate cas number 12168-85-3 without being trained in hazard communication on or about 7/7/14.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339947988.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.