Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PRINCETONIAN GRAPHICS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PRINCETONIAN GRAPHICS, INC. in 45 STOUTS LANE SUITE 4, MONMOUTH JUNCTION, NJ 08852 (NAICS 323111). OSHA activity number 339950297.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Princetonian Graphics, INC. — free Get an email when a new federal OSHA severe-injury report for Princetonian Graphics, INC. is published. One employer, no account, unsubscribe in one click.
Site address
45 STOUTS LANE SUITE 4
City
MONMOUTH JUNCTION
State
NJ
ZIP
08852
Mailing
45 STOUTS LANE SUITE 4, MONMOUTH JUNCTION, NJ 08852
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
11
Ownership type
A

6 citations on file for this inspection.

1910.106 E02 IV D

Serious Gravity 1 1 instance 5 exposed
Issued
Sep 23, 2014
Abate by
Oct 10, 2014
Penalty
Initial $1,020 · Current $612 Reduced
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessel(s), container(s), or portable tank(s) within a building through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tank by gravity through an approved self-closing valve:    a/ Princetonian/Monmouth Jct., NJ Site:  Production/Press Room - Safety can(s) were not used in all areas to dispense and store Category 2 flammable liquid(s) flash point 105 degrees F including but not limited to Prisco Power Klene WM containing Ethanol.     Observed on/or about 09/12/2014.
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

1910.212 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 23, 2014
Abate by
Oct 20, 2014
Penalty
Initial $1,360 · Current $816 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts.     a/ Princetonian/Monmouth Jct., NJ Site: Production/Press Room - Hamada RS34 Printing Press - Rollers approx. 13 inches long and 1.5 to 2.0 inches in diameter were not guarded to prevent accidental contact with in-running nip   point(s) during operation.    Observed on/or about 09/12/2014.
Recent events (2)
  • — I (S) $816
  • — Z (S) $1360

1910.305 A02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 23, 2014
Abate by
Oct 10, 2014
Penalty
Initial $1,020 · Current $612 Reduced
29 CFR 1910.305(a)(2)(i):  Temporary electrical power and lighting rated 600 volts, nominal, or less were used for purposes other than those permitted in subparagraphs (a), (b), and (c) of this paragraph 1910.305(a).  Temporary wiring was used for permanent use.     a/ Princetonian/Monmouth Jct., NJ Site:  Production/Press Room - An extension cord was used in lieu of permanent wiring to power an attachment to the RS34 Hamada printing press.    Observed on/or about  09/12/2014
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

1910.1200 F05

Other-than-serious 1 instance 5 exposed
Issued
Sep 23, 2014
Abate by
Oct 17, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5):   The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity the hazardous chemical(s) contained therein:    a/  Princetonian/Monmouth Jct., NJ Site: Production/Press Room:  Secondary containers including but not limited to:  Containers of Fountain Solution and Alcohol Substitute (approx. 5 gal. capacity) were not marked.      Observed on/or about 09/12/2014.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H02

Other-than-serious 1 instance 8 exposed
Issued
Sep 23, 2014
Abate by
Oct 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(2):  Employees were not provided information and training on the new 2012 Hazard Communication Global Harmonizing System:  a/ Princetonian/Monmouth Jct., NJ Site:  Training was not provided to employees on the new chemical Data Sheets and Labeling - effective December 1, 2013. Chemicals include but not limited to Blanket Wash/Prisco Power Klene, Printing Ink and Alcohol Substitute.  Observed on/or about 09/12/2014.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 L04 III

Other-than-serious 1 instance 3 exposed
Issued
Sep 23, 2014
Abate by
Oct 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): The employer did not ensure that an evaluation of each powered industrial truck operators performance was conducted at least once every 3 years.   a/ Princetonain/Monmouth Jct. Site: Production. Hyster Mechanical Walk Behind Hand Truck - Lift truck operator(s) who were previously trained were not evaluated relative to their previous forklift training at least once every three years.   Observed on/or about 09/12/2014.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Princetonian Graphics, INC.'s full OSHA safety record →