ATLANTA, GA —
OSHA Inspection: ALL SOUTH ELECTRICAL CONSTRUCTORS INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of ALL SOUTH ELECTRICAL CONSTRUCTORS INC. in 280 ELIZABETH STREET, ATLANTA, GA 30307 (NAICS 238210). OSHA activity number 339950339.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALL SOUTH ELECTRICAL CONSTRUCTORS INC.
- Site address
- 280 ELIZABETH STREET
- City
- ATLANTA
- State
- GA
- ZIP
- 30307
- Mailing
- 150 KELLI CLARK COURT SUITE A, CARTERSVILLE, GA 30121
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 1
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.502 I02
- Issued
- Mar 3, 2015
- Penalty
- Initial $2,800 · Current $2,240 Reduced
General-duty citation text
29 CFR 1926.502(i)(2): All other covers were not capable of supporting, without failure, at least twice the weight of the employees, equipment, and materials that maybe be imposed on the cover at any one time: (a) An OSB sheathing used to cover a roof vent shaft opening was not capable of supporting, without failure, at least twice the weight that could be imposed on the cover. The vent shaft opening was approximately 56-feet, 8-inches above the next lower level. The employer is cited as a controlling employer at a multi-employer worksite that included other subcontractors.
Recent events (3)
- — F (S) $2240
- — C (S) $2800
- — Z (S) $2800
1926.502 I03
- Issued
- Mar 3, 2015
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees: (a) An OSB sheathing that was used to cover a roof vent shaft opening that was approximately 69-inches by 42-inches was not secured to prevent accidental displacement. The vent shaft opening was approximately 56-feet, 8-inches above the next lower level. Employer is being cited under OSHA's multi-employer citation policy as the "exposing" employer.
Recent events (3)
- — F (S) $0
- — C (S) $2800
- — Z (S) $2800
1926.502 I04
- Issued
- Mar 3, 2015
- Penalty
- Initial $0 · Current $2,240
General-duty citation text
29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard: (a) An OSB sheathing that was used to cover a roof vent shaft opening that was approximately 69-inches by 42-inches was not color coded or marked to provide warning of the hazard. The vent shaft opening was approximately 56-feet, 8-inches above the next lower level. The employer is cited as a controlling employer at a multi-employer worksite that included other subcontractors.
Recent events (3)
- — F (S) $2240
- — C (S) $0
- — Z (S) $0
More inspections at ALL South Electrical Constructors INC.
View ALL South Electrical Constructors INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339950339.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.