Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: J.E. FOURNIER CHIMNEY AND ROOFING CONTRACTORS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of J.E. FOURNIER CHIMNEY AND ROOFING CONTRACTORS, INC. in 25 WOODLAND ST, WORCESTER, MA 01610 (NAICS 238160). OSHA activity number 339955197.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J.E. Fournier Chimney and Roofing Contractors, INC. for free Get an email when a new federal OSHA severe-injury report for J.E. Fournier Chimney and Roofing Contractors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
25 WOODLAND ST
City
WORCESTER
State
MA
ZIP
01610
Mailing
21 N QUINSIGAMOND AVE, SHREWSBURY, MA 01545
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
Private (A)

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 25, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  25 Woodland St, Worcester MA: On or about 9/17/14, employees were engaged in removing old roofing materials from the roof of a three-story residence and were not protected from fall hazards.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1926.1053 B12

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 25, 2014
Abate by
Oct 1, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive siderails:  25 Woodland St, Worcester MA: On or about 9/17/14, employees used a ladder with aluminum siderails where the employee or the ladder could contact exposed energized electrical equipment.