Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: BRUNDAGE-BONE CONCRETE PUMPING INC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of BRUNDAGE-BONE CONCRETE PUMPING INC in 1016 S SUMMIT, ARKANSAS CITY, KS 67005 (NAICS 238110). OSHA activity number 339955627.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Brundage-Bone Concrete Pumping INC for free Get an email when a new federal OSHA severe-injury report for Brundage-Bone Concrete Pumping INC is published. One employer, no account, unsubscribe in one click.
Site address
1016 S SUMMIT
City
ARKANSAS CITY
State
KS
ZIP
67005
Mailing
3131 N HILLSIDE ST, WICHITA, KS 67219
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
20
Ownership type
Private (A)

2 citations on file for this inspection.

1926.416 A01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jan 12, 2015
Abate by
Feb 11, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:  On or About 9/15/2014 and dates prior, at the site located at 1016 S Summit, Arkansas City, Kansas - the employer did not ensure that the boom of the Putzmeister Model BSF40Z concrete pump did not maintain a safe distance from the 7200 volt electrical power distribution line. Employees were exposed to a electrocution hazard.
Recent events (3)
  • · F (S) $0
  • · C (S) $7000
  • · Z (S) $7000

1926.416 A03

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jan 12, 2015
Abate by
Feb 11, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1926.416(a)(3): Employer did not advise employees of the location of energized electrical power circuits, the hazards involved, and the protective measures to be taken:  On or about 9/15/2014 and dates prior, at the site located at 1016 S Summit, Arkansas City, Kansas - the employer did not adequately advise employee/s operating concrete placing equipment such as but not limited to a Putzmeister Model BSF40Z concrete pump of the location of the energized 7200 volt electrical power distribution lines. Employees were exposed to a electrocution hazard.
Recent events (3)
  • · F (S) $0
  • · C (S) $7000
  • · Z (S) $7000

View Brundage-Bone Concrete Pumping INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339955627.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.