WILLIAMSON, NY —
OSHA Inspection: THATCHER COMPANY OF NEW YORK, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of THATCHER COMPANY OF NEW YORK, INC. in 4135 ROUTE 104, WILLIAMSON, NY 14589 (NAICS 325180). OSHA activity number 339963100.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THATCHER COMPANY OF NEW YORK, INC.
- Site address
- 4135 ROUTE 104
- City
- WILLIAMSON
- State
- NY
- ZIP
- 14589
- Mailing
- PO BOX 118, WILLIAMSON, NY 14589
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325180
- Employees
- 23
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.119 J02
- Issued
- Mar 19, 2015
- Abate by
- Apr 23, 2015
- Penalty
- Initial $5,000 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.119(j)(2): The employer did not establish or implement written procedures to maintain the on-going integrity of process equipment. a) At the facility, on or about 11/12/14: Written procedures were not established to ensure on-going mechanical integrity of pressure gauges for SO2 piping and the R3 reactor. Abatement certification must be submitted for this item.
Recent events (3)
- — J (O) $2000
- — C (S) $5000
- — Z (S) $5000
1910.119 J04 IV
- Issued
- Mar 19, 2015
- Abate by
- Apr 23, 2015
- Penalty
- Initial $5,000 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.119(j)(4)(iv): The employer did not document each inspection and test that had been performed on process equipment. The documentation did not identify the date of the inspection or test, the name of the person who performed the inspection or test, the serial number or other identifier of the equipment on which the inspection or test was performed, a description of the inspection or test performed, and the results of the inspection or test. a) On piping of the covered process, on or about 9/24/14: Documentation of annual thickness measurements taken on process piping did not identify the specific location on pipes where the measurement was taken. b) On the R3 reactor, on or about 9/24/14: Thickness measurements taken on the R3 reactor were not documented. Abatement certification must be submitted for these items.
Recent events (3)
- — J (O) $2000
- — C (S) $5000
- — Z (S) $5000
1910.119 D03 I B
- Issued
- Mar 19, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(d)(3)(i)(B): Information pertaining to the equipment in the process did not include piping and instrument diagrams (P&ID's): a) On the P&ID drawing, on or about 9/24/14: A valve (BV-SO2-12) depicted on the SO2 vent line of the drawing was not present in the facility. b) On the P&ID drawing, on or about 9/24/14: A pressure indicator for the expansion chamber on the SO2 liquid line was not depicted on the drawing. c) On the P&ID drawing, on or about 9/24/14: A valve (BV-R3-SO2-4) depicted on the SO2 liquid line of the drawing was not present in the facility.
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
1910.119 D03 II
- Issued
- Mar 19, 2015
- Abate by
- Apr 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices. a) For piping on the covered process, on or about 11/4/14: The employer did not document that pipe labeling complied with recognized and generally accepted good engineering practices. Abatement certification must be submitted for this item.
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
1910.119 F03
- Issued
- Mar 19, 2015
- Abate by
- Apr 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(f)(3): The employer did not annually certify that operating procedures were current and accurate. a) At the facility, on or about 9/24/14: The employer did not certify annually that operating procedures for the covered process were current and accurate. Abatement certification must be submitted for this item.
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Thatcher Company of NEW York, INC.
View Thatcher Company of NEW York, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325180)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339963100.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.