MIDDLE VILLAGE, NY ·
OSHA Inspection: SAINT JOHN?S CEMETERY CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SAINT JOHN?S CEMETERY CORPORATION in 80-01 METROPOLITAN AVE, MIDDLE VILLAGE, NY 11379 (NAICS 812220). OSHA activity number 339967002.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAINT JOHN?S CEMETERY CORPORATION
- Site address
- 80-01 METROPOLITAN AVE
- City
- MIDDLE VILLAGE
- State
- NY
- ZIP
- 11379
- Mailing
- 80-01 METROPOLITAN AVE, MIDDLE VILLAGE, NY 11379
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 812220
- Employees
- 97
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1926.20 B02
- Issued
- Jan 30, 2015
- Abate by
- Apr 30, 2015
- Penalty
- Initial $3,500 · Current $1,700 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): a) On or about September 5, 2014 - Jobsite at Section 45 Farmville Avenue and 80th Street Middle Village, NY 11379 There was no competent person to identify the lack of a railing system for walking on plank 19-inches wide, across a 2-foot wide excavation, 8-feet above the next lower level, or inadequate shoring systems. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (3)
- · J (S) $1700
- · C (S) $3500
- · Z (S) $3500
1926.651 K01
- Issued
- Jan 30, 2015
- Abate by
- Mar 19, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift: a) On or about September 5, 2014 - Jobsite at Section 45 Farmville Avenue and 80th Street Middle Village, NY 11379 Management did not provide a competent person able to identify that Excavations in previously disturbed soil up to 8-feet in depth requires proper sloping at 1:1 or a shoring system engineered or equal to Subpart P shoring tables. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (3)
- · J (S) $0
- · C (S) $0
- · Z (S) $0
1926.651 L
- Issued
- Jan 30, 2015
- Abate by
- Feb 26, 2015
- Penalty
- Initial $4,900 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.651(l): Guardrails complying with 1926.502(b) were not provided where walkways were 6 feet (1.8m) or more above lower levels: a) On or about September 5, 2014 - Jobsite at Section 45 Farmville Avenue and 80th Street Middle Village, NY 11379 Management permitted an employee to work from an unsecured 19-inches wide working plank without a railing to prevent falls while above an excavation at least 32-inches wide, and up to 8-feet in deep.
Recent events (3)
- · J (S) $2500
- · C (S) $4900
- · Z (S) $4900
1926.652 A01
- Issued
- Jan 30, 2015
- Abate by
- May 31, 2015
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). The employer had not complied with the provisions of 29 CFR 1926.652(b)(1)(i) in that the sloping or benching system design was not followed: a) On or about September 5, 2014 - Jobsite at Section 45 Farmville Avenue and 80th Street Middle Village, NY 11379 Management permitted employees to use timber shoring 1.25-inches thick, 6-inches wide, laid as wails should be and 2-inch diameter steel bars with rope tie backs, as uprights that did meet the minimum criteria for timber shoring at depths of 5-feet to 8-feet. Employees did not understand the use of a 1:1 slope as a protective system.
Recent events (3)
- · J (S) $2450
- · C (S) $4900
- · Z (S) $4900
1926.652 E01 II
- Issued
- Jan 30, 2015
- Abate by
- May 31, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(e)(1)(ii): Support systems were not installed and removed in a manner that protected employees from cave-ins, structural collapses, or from being struck by members of the support system: a) On or about September 5, 2014 - Jobsite at Section 45 Farmville Avenue and 80th Street Middle Village, NY 11379 Management permitted employees to work in excavations exposed to collapse hazards while installing a shoring system from the bottom up and removing it from the top down at depths of up to 8-feet below the next level.
Recent events (3)
- · J (S) $0
- · C (S) $0
- · Z (S) $0
1926.652 E01 III
- Issued
- Jan 30, 2015
- Abate by
- May 31, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(e)(1)(iii): Individual members of support systems were subjected to loads exceeding those which those members were designed to withstand: a) On or about September 5, 2014 - Jobsite at Section 45 Farmville Avenue and 80th Street Middle Village, NY 11379 Management permitted employees to use timber shoring 1.25-inches thick, 6-inches wide, laid as wails should be and 2-inch diameter steel bars with rope tie backs, as uprights that did meet the minimum criteria for timber shoring at depths of 5-feet to 8-feet.
Recent events (3)
- · J (S) $0
- · C (S) $0
- · Z (S) $0
1910.1200 E01
- Issued
- Jan 30, 2015
- Abate by
- Mar 19, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: Management allows employees to use gasoline, diesel fuel, and, paints without a written hazard communication program or HAZCOM program to identify the location of safety data sheets, who to speak to about questions about chemical safety and personal protective equipment (PPE) and chemical protection, and storage training. WRITTON ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (3)
- · J (O) $0
- · C (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 812220)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339967002.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.