HUNTINGTON, NY —
OSHA Inspection: GPC CONTRACTING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GPC CONTRACTING, INC. in 40 GERARD ST, HUNTINGTON, NY 11743 (NAICS 236116). OSHA activity number 339970204.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GPC CONTRACTING, INC.
- Site address
- 40 GERARD ST
- City
- HUNTINGTON
- State
- NY
- ZIP
- 11743
- Mailing
- 21 SHERWOOD DR, SAINT JAMES, NY 11780
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 14
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 B01
- Issued
- Sep 30, 2014
- Abate by
- Oct 6, 2014
- Penalty
- Initial $1,200 · Current $900 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) Worksite, South: Employees were working on the fifth section of a scaffold system. The platform was constructed with two planks, leaving the remaining area unplanked; on, or about, 09/26/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $900
- — Z (S) $1200
1926.451 C01
- Issued
- Sep 30, 2014
- Abate by
- Oct 6, 2014
- Penalty
- Initial $1,200 · Current $900 Reduced
General-duty citation text
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. a) Worksite, South: Employees were working on the fifth section of a scaffold system. A rope was used to tie the eastern most side of the top scaffold section to a post on the third story of a residential building; on, or about, 09/26/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.