OSHA Inspection: JUAN SIFUENTES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JUAN SIFUENTES in 9500 N. SAM HOUSTON PARKWAY, HUMBLE, TX 77396 (NAICS 238140). OSHA activity number 339979312.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Juan Sifuentes — free Get an email when a new federal OSHA severe-injury report for Juan Sifuentes is published. One employer, no account, unsubscribe in one click.
Establishment
JUAN SIFUENTES
Site address
9500 N. SAM HOUSTON PARKWAY
City
HUMBLE
State
TX
ZIP
77396
Mailing
7629 EDNA ST., HOUSTON, TX 77087
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.451 G01

Serious Gravity 10 1 instance 5 exposed
Issued
Oct 6, 2014
Abate by
Oct 24, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.  The employer does not protect each employee on a scaffold more than 10 feet above a lower level from falling. This violation was observed on or about October 2, 2014, on the west side of the building where employees were exposed to a fall hazard of 13 feet when applying stucco siding from fabricated frame scaffolding without being protected from falling to the lower level.  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that each employee on a scaffold more than 10 feet above a lower level are protected from falling to that level.
Recent events (1)
  • — Z (S) $2800

1926.451 G01 V

Serious Gravity 5 1 instance 5 exposed
Issued
Oct 6, 2014
Abate by
Oct 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1)(v): Each employee on a walkway located within a scaffold was not protected by a guardrail system (with a minimum 200 pound toprail capacity) installed within 9.5 inches (24.1 cm) of and along at least one side of the walkway.  The employer does not install guardrail systems along at least one side of walkways within a scaffold. This violation was observed on or about October 2, 2014, on the west side of the building where employees were exposed to a fall hazard of 13 feet when applying stucco siding from fabricated frame scaffolding without the walkways having a guardrail system installed along at least one side.  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that each employee on a walkway located within a scaffold is protected by a guardrail system (with a minimum 200 pound toprail capacity) installed within 9.5 inches (24.1 cm) of and along at least one side of the walkway.
Recent events (1)
  • — Z (S) $0

1926.451 H01

Serious Gravity 1 1 instance 5 exposed
Issued
Oct 6, 2014
Abate by
Oct 24, 2014
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.451(h)(1): Each employee on a scaffold was not provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects.  For falling objects too large, heavy or massive to be contained or deflected, the employer did not place and secure such potential falling objects away from the edge of the surface from which they could fall.  The employer does not protect each employee on a scaffold with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects. This violation was observed on or about October 2, 2014, on the west side of the building where employees were exposed to a struck-by hazard of when applying stucco siding from two levels of fabricated frame scaffolding without being provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling object.   Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that each employee on a scaffold is provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects.
Recent events (1)
  • — Z (S) $1200

1926.452 C02

Serious Gravity 5 1 instance 5 exposed
Issued
Oct 6, 2014
Abate by
Oct 24, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally:  The employer does not ensure frames and panels are braced by cross, horizontal, or diagonal braces, or combination thereof. This violation was observed on or about October 2, 2014, on the west side of the building where employees were exposed to a fall hazard of 13 feet when applying stucco siding from fabricated frame (tubular welded frame) scaffolding without the frames and panels being braced by cross, horizontal, or diagonal, or a combination thereof, which would have secured vertical members together laterally.   Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that tubular welded frames and panels are braced by cross, horizontal, or diagonal braces, or combination thereof, which would secure vertical members together laterally.
Recent events (1)
  • — Z (S) $2000

View Juan Sifuentes's full OSHA safety record →