SOUTHLAKE, TX —
OSHA Inspection: ESTEBAN BRIONES ROOFING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ESTEBAN BRIONES ROOFING in 516 CASCADE SPRINGS DRIVE, SOUTHLAKE, TX 76092 (NAICS 236115). OSHA activity number 339982431.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ESTEBAN BRIONES ROOFING
- Site address
- 516 CASCADE SPRINGS DRIVE
- City
- SOUTHLAKE
- State
- TX
- ZIP
- 76092
- Mailing
- 2405 W. 6TH STREET, IRVING, TX 75060
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.102 A01
- Issued
- Oct 17, 2014
- Abate by
- Nov 17, 2014
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury: This violation occurred on October O3, 2014, at a work site located at 516 Cascade Springs Drive, Southlake, Texas; employees using circular saws were not protected from eye injuries by wearing protective eyewear.
Recent events (1)
- — Z (S) $1200
1926.501 B13
- Issued
- Oct 17, 2014
- Abate by
- Nov 17, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6-feet or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest systems, nor was an alternative fall protection plan which meets the requirements of '1926.502(k) developed and implemented. This violation occurred on October 03, 2014, at a work site located at 516 Cascade Springs Drive, Southlake, Texas; at least three employees, who were walking and working from the roof of a new residential building, were not protected from falling to the lower level by use of guardrail or personal fall arrest system.